Settings
Repeat steps
4
and
5
for all the divisions.
The same camera can be assigned to multiple
divisions.
When setting the structure in a dividing mode that
has multiple pages, the setting display for the
subsequent page will appear by pressing the
b
key
in the last (lower right) division. To return to the
pervious page, press the
B
key in the first (upper
left) division.
To set the selected division to a blank (no
display) division
Set to NO.
If all the divisions of a page are set to “NO, ” that
page will be skipped when monitoring. Similarly,
if all the divisions of a dividing structure are set to
“NO,” that dividing structure will be skipped when
monitoring.
6
When the settings are completed, press the SET
key.
A message “NOW SAVING” is displayed, and the
settings are stored in nonvolatile memory.
The Image Control Menu is restored.
To restore the previous setting
Before pressing the SET key, press the MENU key.
The message “ABORT !” is displayed, and the
previous setting is restored.
To set the playback display structures
Use PLAY DISP STRUCTURE (Play Disp) of the
Image Control menu for making the setting.
1
Highlight IMAGE CONTROL MENU (Image
Menu) of the top menu by pressing the
V
or
v
key,
then press the
b
key.
The Image Control menu (page 4-6) is displayed.
2
Highlight PLAY DISP STRUCTURE (Play Disp)
by pressing the
V
or
v
key, then press the
b
key.
The menu shifts to playback display structure
setting.
SETUP MENU
IMAGE CONTROL MENU
PLAY DISP STRUCTURE
4 DIVISION
6 DIVISION
7 DIVISION
8 DIVISION
9 DIVISION
10 DIVISION
13 DIVISION
16 DIVISION
3
Highlight the desired division mode by pressing
the
V
or
v
key, then press the
b
key.
The setting display of the selected division mode
appears on the monitor screen.
Example: 8-Division mode
CAM 2
CAM 1
CAM 3
CAM 4
CAM 5
CAM 6
CAM 7
(MON)
(PB)
(MON)
(MON)
(MON)
(MON)
(MON)
NO
1 page
4
Select the division to be set by pressing the
b
or
B
key.
Each time you press either of the keys, the next
division is selected, and the indication for the
selected division flash.
5
Select the camera to be monitored in the selected
division by pressing the
V
or
v
key.
Each time you press either of the keys, the camera
numbers of the connected cameras and NO are
cyclically selected.
To assign a playback camera
Set CAM 1(PB) to CAM 16(PB).
You can also specify the camera number by
pressing the corresponding number key.
Chapter 5
Connections and Preparations
Chapter 5
Connections and Preparations
5-11
To assign a monitor camera
Set CAM n (MON).
You can specify the camera number by pressing
the corresponding number key. Note, however,
that the camera set to NO in CAMERA
CONNECTION cannot be selected.
Repeat steps
4
and
5
for all the divisions.
The same camera can be assigned to multiple
divisions.
When setting the structure in a dividing mode that
has multiple pages, the setting display for the
subsequent page will appear by pressing the
b
)
key in the last (lower right) division. To return to
the pervious page, press the
B
key in the first
(upper left) division.
To set the selected division to a blank (no
display) division
Set to NO.
If all the divisions of a page are set to “NO, ” that
page will be skipped when monitoring. Similarly,
if all the divisions of a dividing structure are set to
“NO,” that dividing structure will be skipped when
monitoring.
6
When the settings are completed, press the SET
key.
A message “NOW SAVING” is displayed and the
settings are stored in nonvolatile memory.
The Image Control Menu is restored.
To restore the previous setting
Before pressing the SET key, press the MENU key.
The message “ABORT !” is displayed, and the
previous setting is restored.
Setting the Automatic Change
Cycle
The picture to be monitored in Full screen
(nondivided) mode can be automatically changed at
the specified cycle.
You can determine whether to automatically change
the picture and, if to change, the cycle independently
for the VIDEO OUT A and B connectors.
The S-VIDEO connector always outputs the same
signal as that from the VIDEO OUT A connector.
Use A IMAGE (A Image) and B IMAGE (B Image) of
the Image Control menu.
The setting procedure is common to the A and B
connectors.
To activate the automatic change function
Set MONITOR (Monitor) of A IMAGE (A Image) or
B IMAGE (B Image) to AUTO (Auto).
1
Highlight IMAGE CONTROL MENU (or display
Image Menu) of the top menu by pressing the
V
or
v
key, then press the
b
key.
The Image Control menu (page 4-6) is displayed.
2
Highlight A IMAGE or B IMAGE (or display A
Image or B Image) by pressing the
V
or
v
key, then
press the
b
key.
The menu shifts to corresponding setting.
Example: A Image
SETUP MENU
IMAGE CONTROL MENU
A IMAGE
M
MONITOR
: MANUAL
m
ALARM CHANGE : OFF
AUTO CYCLE
(Continued)
Summary of Contents for HSR-1
Page 70: ......
Page 112: ......
Page 116: ...6 4 HSR 1 1P HSR 2 2P 6 1 3 Loading Unloading 6 1 4 Manual Up Down the FL Block ...
Page 118: ...6 6 HSR 1 1P HSR 2 2P Attach the jigs ...
Page 123: ...6 11 HSR 1 1P HSR 2 2P PHASE ADJUSTMENT K PHASE ADJUSTMENT L PHASE ADJUSTMENT M ...
Page 152: ...6 40 HSR 1 1P HSR 2 2P 6 4 33 Roller Shaft Assembly and Roller Belt Removing Attaching ...
Page 153: ...6 41 HSR 1 1P HSR 2 2P 6 4 34 LID Opener Removing Attaching ...
Page 156: ...6 44 HSR 1 1P HSR 2 2P 6 5 ADJUSTMENTS AND CHECKS 6 5 1 Adjustment Position ...
Page 157: ...6 45 HSR 1 1P HSR 2 2P 6 5 2 Adjustment Order ...
Page 161: ...6 49 HSR 1 1P HSR 2 2P 4 Adjustment order ...
Page 170: ...6 58 HSR 1 1P HSR 2 2P 6 6 SERVICE MODE 6 6 1 Data Processing ...
Page 171: ...6 59 HSR 1 1P HSR 2 2P 6 6 2 Service Mode ...
Page 172: ...6 60 HSR 1 1P HSR 2 2P 6 6 3 System Control Adjustment ...
Page 173: ...6 61 HSR 1 1P HSR 2 2P ...
Page 174: ...6 62 HSR 1 1P HSR 2 2P ...
Page 175: ...6 63 HSR 1 1P HSR 2 2P 6 6 4 Servo System Adjustments ...
Page 176: ...6 64 HSR 1 1P HSR 2 2P 6 6 5 Video System Adjustments 6 6 5 1 RP 228 Board Adjustments ...
Page 177: ...6 65 HSR 1 1P HSR 2 2P ...
Page 178: ...6 66 HSR 1 1P HSR 2 2P ...
Page 179: ...6 67 HSR 1 1P HSR 2 2P ...
Page 180: ...6 68 HSR 1 1P HSR 2 2P 6 6 6 Location Diagram of Adjustment Related Parts ...
Page 181: ...6 69 HSR 1 1P HSR 2 2P ...