Setting item
Allowable settings
Description
(Continued)
Detail1
Detail
ON, OFF
Turns ON or OFF the feature of adding a detail signal for
resolution enhancement
Level
–99 to +99
Sets the overall level of the detail signal
Limiter
–99 to +99
Sets the clipping level for an excessive value of the detail
signal
Crispening
–99 to +99
Sets the crispening restricting the detail with respect to noise
H/V ratio
–99 to +99
Sets the mixing ratio of the horizontal and vertical detail
signals
Frequency
–99 to +99
Sets the frequency of the horizontal detail signal
Level DEP
–99 to +99
Sets the level at which the amount of detail is suppressed
in areas of low level
Level DEP
ON, OFF
Sets the level dependancy feature to ON or OFF
Clear
Push the MENU SEL
control to execute
Resets all Detail1 page settings to 0.
(When the MENU SEL control is pushed, the CLEAR display
will blink. Pushing the MENU SEL control again will execute
the clear; pressing the CANCEL button will cancel.)
Clear
Push the MENU SEL
control to execute
Resets all Gamma page settings to 0.
(When the MENU SEL control is pushed, the CLEAR display
will blink. Pushing the MENU SEL control again will execute
the clear; pressing the CANCEL button will cancel.)
Knee1
Point R,G,B,M
–99 to +99
Sets the knee point level for when the auto knee feature is
turned OFF
Slope R,G,B,M
–99 to +99
Sets the knee slope level for when the auto knee feature is
turned OFF
W.CLP R,G,B,M
–99 to +99
Sets the white clip level
Knee
ON, OFF
Turns the knee correction circuit ON or OFF
Auto Knee
ON, OFF
Turns the auto knee feature ON or OFF
White Clip
ON, OFF
Turns the white clip feature ON or OFF
Test
1, 2, OFF
Selects test signal
1: Sawtooth wave test output
2: Three-step waveform test output
OFF: No test signal output
Clear
Push the MENU
SEL control to
execute
Resets all Knee1 page settings to 0.
(When the MENU SEL control is pushed, the CLEAR display
will blink. Pushing the MENU SEL control again will execute
the clear; pressing the CANCEL button will cancel.)
Knee Saturation
–99 to +99
Adjusts the knee saturation feature
Knee SAT Level
ON, OFF
Turns the knee saturation feature ON or OFF
Super Skin Knee
ON, OFF
Turns the super skin knee feature ON or OFF
Test
1, 2, OFF
Selects test signal
1: Sawtooth wave test output
2: Three-step waveform test output
OFF: No test signal output
Knee2
Clear
Push the MENU SEL
control to execute
Resets all Knee2 page settings to 0.
(When the MENU SEL control is pushed, the CLEAR display
will blink. Pushing the MENU SEL control again will execute
the clear; pressing the CANCEL button will cancel.)
Summary of Contents for HDC-750A
Page 4: ...目次 2 J 目 次 第5章 撮影 付録 仕様 A 1 J 撮影前の点検 A 2 J 防塵フィルターのクリーニング A 3 J 用語解説 A 4 J 5 1 撮影操作 5 1 J ...
Page 12: ......
Page 18: ......
Page 30: ......
Page 52: ......
Page 59: ...付録 A 5 J 付 録 ...
Page 66: ......
Page 72: ......
Page 84: ......
Page 106: ......