5-30
Fig. 5-1-17.
A
2H
1. VCO Adjustment (PD-138/139 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
8
of CN5502 (HSY)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
A2, A3
Specified Value
f = 15625 ± 30Hz
Note1:
Refer to “LCD Type Check” for the discrimination of the LCD
type.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
A2
Change the data and set the VCO
frequency (f) to the specified value.
3
D
A2
Press PAUSE button.
4
D
A2
Read the data, and this data is named
D
A2
.
5
Convert D
A2
to decimal notation,
and obtain D
A2
’. (Note2)
6
Calculate D
A3
’ using following
equations (Decimal calculation)
[2.5 LCD TYPE SO (61k)]
When D
A2
’ 20
D
A3
’= D
A2
’–20
When D
A2
’< 20
D
A3
’ = 0
[2.5 LCD TYPE SO (123k)]
When D
A2
’ 26
D
A3
’=D
A2
’ – 26
When D
A2
’ < 26
D
A3
’=0
[3.0 LCD TYPE SH (123k)]
When D
A2
’ 28
D
A3
’=D
A2
’– 28
When D
A2
’ < 28
D
A3
’=0
[3.5 LCD TYPE SO (123k)]
When D
A2
’ 9
D
A3
’=D
A2
’–9
When D
A2
’ < 9
D
A3
’=0
7
Convert D
A3
’ to a hexadecimal
number, and obtain D
A3
. (Note2)
8
D
A3
D
A3
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2:
Refer to “Table 5-4-1. Hexadecimal-decimal Conversion Table”.
2. PSIG Gray Adjustment (PD-139 board)
(DCR-TRV230E/TRV235E/TRV325E/TRV330E/TRV530E)
Set the uniformity improvement signal to an appropriate level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin
4
of CN5502 (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A7
Specified Value
A = 5.00 ± 0.1V
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
A7
Change the data and set the PSIG
signal level (A) to the specified value.
(The data should be “00” to “7F”)
3
D
A7
Press PAUSE button.
4
0
01
00
Set the data.
Summary of Contents for Handycam DCR-TRV230E
Page 117: ...DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E 4 69 4 70 USER FUNCTION EVF DRIVE CF 079 ...
Page 119: ...DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E 4 73 4 74 USER FUNCTION EVF DRIVE CF 080 ...
Page 142: ...5 1 DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E SECTION 5 ADJUSTMENTS ...
Page 239: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 304 OPTICAL AXIS FRAME ...