![Sony Handycam DCR-TRV230E Service Manual Download Page 189](http://html.mh-extra.com/html/sony/handycam-dcr-trv230e/handycam-dcr-trv230e_service-manual_1323201189.webp)
5-48
7. CAP FG Offset Adjustment (VC-254 board)
Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur in the Hi8/Standard8 LP mode.
Mode
Playback
Signal
Hi8/standard 8 alignment tape :
For checking operation
(WR5-5CSP)
Measurement Point
Pin
qg
of CN1108 (CAP FG)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
64
Specified value
Duty = 50 ± 1 %
Adjusting method:
Order Page Address Data
Procedure
1
Set to the stop mode.
2
0
01
01
Set the data.
3
2
2E
02
Set the data.
4
Set to the playback mode.
5
6
01
81
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”.
7
6
01
00
Set the data, and press PAUSE
button.
8
Check that Duty of CAP FG
signal satisfies the specified
value. If not, repeat steps 5 to 8.
9
2
2E
00
Set the data.
10
0
01
00
Set the data.
Fig. 5-3-7.
A
B
Duty = A/B
×
100 [%]
Center of movement
Summary of Contents for Handycam DCR-TRV230E
Page 117: ...DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E 4 69 4 70 USER FUNCTION EVF DRIVE CF 079 ...
Page 119: ...DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E 4 73 4 74 USER FUNCTION EVF DRIVE CF 080 ...
Page 142: ...5 1 DCR TRV230E TRV235E TRV325E TRV330E TRV430E TRV530E SECTION 5 ADJUSTMENTS ...
Page 239: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 304 OPTICAL AXIS FRAME ...