background image

5-7(E)

FDDR-7000 IM

5-4. Resource Setup Using the Initial Setup Tool

8.

Shut down the FARAD system.

9.

Start up the FARAD system.

When the SYSTEM indicator of the FDDR-7000 lights, setup of the resource using the initial setup

tool is complete.

The resource setting made here remains saved in the system even after turning off the main power.

n

If the SYSTEM indicator of the FDDR-7000 flashes, it means that the resource has not been set up

correctly.

Perform from step 4 and set the resource again.  (The location of the error is displayed by the 7-

segment LED (ND300 and ND301) on the CPU-253 board.  Refer to Maintenance Manual Part-1

section “3. Diagnostics Function.”)

5-4-2. When Two or More FDDR-7000s Are Connected to the Host Computer

1.

Start up the system.

n

Since the resource has not been set yet, a system malfunction is detected and the SYSTEM indicator

of the FDDR-7000 flashes.  However, the resource can be set using the initial setup tool.

2.

Start up Windows NT.

3.

Insert the CD-R supplied with the operating software BZFD-7020 into the CD-ROM drive of the

personal computer.

4.

Start up the command prompt in Windows NT.

5.

Change the current directory from the Windows NT root directory to the CD-R’s Tool directory.

6.

Enter  faradres -d farad.  (Carriage return)

The resource setup screen of FDDR-7000 specified by -d appears.

The same screen as shown in step 6 of section “5-4-1. When One FDDR-7000 is Connected to the

Host Computer” appears.  Perform the procedure described in section 5-4-1 step 7 and later to set the

resource of the system.

n

Letter “d” of faradres -d farad becomes the Device shown in step 8 of the procedure for installing the

operating software.

(Example: faradres -d ha0d6l0)

Summary of Contents for FDDR-7000

Page 1: ... 7000 INSTALLATION MANUAL 1st Edition Revised 1 BKFD 7800 HDD UNIT BKFD 7009 7009A HDD EXTENSION BOX VIDEO CHANNEL BOARD SET BKFD 7110 VIDEO PROCESS BOARD BKFD 7120 SCSI BOARD BKFD 7500 AUDIO BOARD BKFD 7600 OPERATION SOFTWARE BZFD 7010 7020 ...

Page 2: ...niquement Attention when the product is installed in Rack 1 Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack please make sure that the rack does not overload the supply circuit 2 Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack please confirm...

Page 3: ... E 1 6 Installation of Power Unit 1 14 E 1 6 1 FDDR 7000 Multi channel digital disk recorder 1 14 E 1 6 2 BKFD 7800 HDD extension box 1 14 E 1 7 List of Supplied Accessories 1 15 E 1 7 1 FDDR 7000 1 15 E 1 7 2 BKFD 7800 1 15 E 1 8 Accessories 1 15 E 1 8 1 FDDR 7000 1 15 E 1 8 2 BKFD 7800 1 15 E 2 Installation of Options 2 1 Location of Main Parts 2 1 E 2 1 1 FDDR 7000 Multi channel digital disk re...

Page 4: ... 4 2 Input and Output Signals of Connectors 4 2 E 4 2 1 FDDR 7000 Multi channel digital disk recorder 4 2 E 4 2 2 BKFD 7800 HDD extension box 4 7 E 5 System Setup 5 1 Initial Setup 5 1 E 5 2 System Startup and Shut Down 5 1 E 5 2 1 System Startup 5 1 E 5 2 2 System Shut Down 5 2 E 5 3 Installation of Operation Software 5 3 E 5 4 Resource Setup Using the Initial Setup Tool 5 6 E 5 4 1 When One FDDR...

Page 5: ...ual Supplied with FDDR 7000 This manual explains the overview of FDDR 7000 and options and the system configuration examples Part number 3 860 507 03 Operation and Maintenance Guide Supplied with BKDF 7600 BKFD 7800 or BKFD 7009 7009A 7120 7110 7500 Part number 3 865 595 01 BKFD 7600 Part number 3 860 508 01 BKFD 7800 Part number 3 860 509 03 BKFD 7009 7009A 7120 7110 7500 Maintenance Manual Part ...

Page 6: ......

Page 7: ...ation resistance characteristics for hard disks both while the vehicle is stopped and moving The hard disk non operation specifications of impact resistance characteristics and vibration resistance characteristics must also be satisfied when a vehicle containing a hard disk moves Temperature range Operating temperature 5 to 40 dC 41 to 104 dF Performance warranty 10 to 35 dC 50 to 95 dF Storage te...

Page 8: ... 2 0 A AC100 V to 0 9 A AC240 V maximum with four HDD unit BKFD 7009 7009A installed A switching regulator is used for the power supply of FDDR 7000 Multi channel digital disk recorder and BKFD 7800 HDD extension box The voltage within the range of 100 V to 240 V can be used without changing the supply voltage n As the inrush current at turn on is the maximum 14 A FDDR 7000 4 8 A BKFD 7800 the cap...

Page 9: ...ce If the units are attached in a wobbly table or a slant surface the units may be dropped This may cause a injury 2 Install the unit in a level 3 When a BKFD 7009 7009A is installed in a vehicle use impact absorbing materials such as shock absorber etc such that the internal hard disk non operation specifications of the impact resistance characteristics and the vibration resistance characteristic...

Page 10: ...0 IM 1 3 Space for Attachment 8 M4 98 7 304 8 254 101 6 22 44 37 57 2 37 132 4 3 UNIT 482 465 424 23 5 5 5 5 7 16 3 29 29 465 Unit mm Mass 29 kg 63 lb 14 oz with all units installed 1 3 2 BKFD 7800 HDD extension box ...

Page 11: ...rail when rack mounting The unit cannot be installed completely to a rack by rack angles alone 3 It is recommended to fix the rack to the floor with bolts When the unit is pulled out from the rack this will prevent its fall 4 An installation manual is supplied with the rack mount rail RMM FD7000 Refer to installation manual RMM FD7000 also 5 Be sure to mount in the rack with two person or more 6 D...

Page 12: ...the outer member 1 by the eight screws B4 x 8 supplied with the RMM FD7000 To see the screw hole of the outer member 1 move the outer member 2 back and forth 4 Temporarily secure the bracket to the outer member assembly 1 to both sides of the rack by the eight screws C4 x 12 and the eight washers W4 supplied with RMM FD7000 Adjust the installation position of the outer member to meet the specifica...

Page 13: ...DDR 7000 Maximum moving distance 470 Distance to slide rail center Set height when mounted in rack 221 5 443 465 7 After installing the unit in the rack secure the unit to the rack by the prepared four screws RK5 x 16 and the four ornamental washers Fig 6 When FDDR 7000 is mounted in a rack the maximum traveling distance is illustrated below ...

Page 14: ...in the rack are operated within the temperature range of 10 dC to 35 dC 2 Be sure to use the recommended rail when rack mounting The unit cannot be completely attached to a rack by rack angles alone 3 To prevent the unit fall when pulling it out from the rack be sure to fix the rack to the floor with bolts 4 An installation manual is included with the rack mount rail RMM 30 The rack mounting proce...

Page 15: ... secure the front and rear brackets to the outside of the rack by the eight screws B5 x 8 included with RMM 30 5 Fully press the inner members to the outer members while pressing the stoppers of the inner members and attach the unit in the rack 6 After confirming that the unit can be moved smoothly tighten the eight screws B5 x 8 temporarily secured in the step 4 n When securing the front brackets...

Page 16: ... BKFD 7800 is mounted in a rack the maximum traveling distance is showed as below 1 4 Rack Mounting Maximum traveling distance 581 Distance to the center of the slide rail Height of the unit mounted in a rack 66 132 4 Unit mm ...

Page 17: ...power switch off while recording or playback is in progress recorded material or system information may be lost and the system will not subse quently function correctly When the BKFD 7800 HDD extension box is connected power on the BKFD 7800 first and then the FDDR 7000 Do not power on the host computer until after all connect ed FARAD systems are powered on 1 Front Panel 1 Turn off the power swit...

Page 18: ...ht 5 Install the side plate right in the reverse order of the steps 1 through 4 4 Side Plate Left w Allow for more than five minutes interval after turning the power off remove the power unit To avoid shock hazards never remove the power unit just after turning the power off 1 Turn off the power switch 2 Remove the front panel Refer to 1 Front Panel in this section 3 Remove the eight screws B4 x 5...

Page 19: ... and the system will not subse quently function correctly When the BKFD 7800 is connected power on the BKFD 7800 first and then the FDDR 7000 Do not power on the host computer until after all connected FARAD systems are powered on 1 Front Panel 1 Turn off the power switch 2 Remove the two screws and the front panel 3 Install the front panel in the reverse order of the steps 1 and 2 2 Upper Chassis...

Page 20: ...1 Turn off the power switch 2 Remove the front panel Refer to 1 Front Panel in the section 1 5 1 3 Insert the power unit 4 Secure the power unit by four screws 1 6 2 BKFD 7800 HDD extension box n Before powering off the BKFD 7800 it is necessary to prepare for shutdown with the SHUTDOWN button of the FDDR 7000 Multi channel digital disk recorder If you simply turn the power switch off while record...

Page 21: ...I Cable Connected to FDDR 7000 4 1 782 529 11 1 8 Accessories 1 8 1 FDDR 7000 Part Description Quantity Part No Product Power Cord U S A and Canada 1 1 558 527 11 Power Cord United Kingdom 1 DK 2401 EK Power Cord 1 DK 2401 AE European Countries except the United Kingdom Extension board EX 578 _ J 6520 150 A Rack Mount Rail RMM FD7000 _ Product 1 8 2 BKFD 7800 Part Description Quantity Part No Prod...

Page 22: ......

Page 23: ...r the BKFD 7800 HDD extension box Option Function name BKFD 7009 7009A HDD unit 2 1 1 FDDR 7000 Multi channel digital disk recorder 1 Plug in Boards FDDR 7000 can be used for various systems and its functions can be extended by selecting the optional boards Each plug in board must be installed in the corresponding slot of the FDDR 7000 Confirm that all the boards are in the specified slots by refe...

Page 24: ...el board 4 DI 32 4 Video channel board 6 VPR 31 6 Video process board 8 DIO 47 9 CPU 253 9 CPU board 3 SD 46A 3 BKFD 7110 Video channel board set 5 DI 32 5 BKFD 7110 Video channel board set 7 VPR 31 7 BKFD 7120 Video process board SCS 15 BKFD 7500 SCSI board 8 BKFD 7600 Audio board DPR 88 0 DAP 16 DPR 101 BKFD 7110 Video channel board set BKFD 7600 Audio board BKFD 7600 Audio board SCS 15 DPR 88 D...

Page 25: ...disk recorder it is necessary to prepare for shutdown with the SHUTDOWN button If you simply turn the power switch off while recording or playback is in progress recorded material or system information may be lost and the system will not subsequently function correct ly When the BKFD 7800 HDD extension box is connected power on the BKFD 7800 first and then the FDDR 7000 Do not power on the host co...

Page 26: ...nect the plug in board to the connector on the mother board by putting the eject levers in the direction of the arrow 2 9 Install the board retainer and the fans in the reverse order of the steps 1 through 4 m 1 Confirm that the connectors on each board are securely connected to the MB 694 board of the unit 2 If the board is installed in an incorrect slot a system error occurs Then the system is n...

Page 27: ...g order Install each optional boards by referring to the following table If the optional board is installed in an incorrect order the system is not activated properly VPR 31 board Install the VPR 31 board in the order of the slot number 3 and 4 Type 2 This Type s Optional Boards Slot No Optional board Pre installed board 1 DI 32 board VIO 30 board BKFD 7110 SD 46A board VIO 30 board BKFD 7110 1 Af...

Page 28: ...annot be connected completely the optional board may be placed in the other way 3 Install the optional board by the DPR bracket and the screws PSW3 x 6 n When installing the one DPR 88 board in the SCS 15 board be sure to put the two D washers as shown in the right figure n Each optional boards must be installed in the corresponding order Install each optional boards by referring to the following ...

Page 29: ...can be installed in a BKFD 7800 Maximum seventeen units of BKFD 7009 7009A can be used in a FARAD system 2 Install BKFD 7009 7009A after installations such as racks etc of FDDR 7000 and BKFD 7800 are completed 3 When installing BKFD 7009 7009A install it into FDDR 7000 then BKFD 7800 connected EXT HDD1 SCSI 1 4 and BKFD 7800 connected EXT HDD2 SCSI 1 4 in this order starting sequentially from disk...

Page 30: ...k of BKFD 7009 7009A is stopped after about one minute has elapsed 4 When installing the FDDR and BKFDs observe the following installation sequence Install the FDDR 7000 first then the BKFD 7800 connected to EXT HDD 1 SCSI 1 4 and then the BKFD 7800 connect ed to EXT HDD 2 SCSI 1 4 in this order starting from disk slot No 1 of the respective equipment BKFD 7009 7009A for the seventeenth unit insta...

Page 31: ...any other HDD becomes defective in this condition the recorded data cannot be recovered 4 When a HDD becomes defective contact Sony s service organization to avoid the above described danger Do not operate the system for a long time in which defective HDD is mounted n BKDF 7009 7009A can not be exchanged while it is operating Be sure to shut down the main power of the FARAD system 5 In the case of...

Page 32: ...n 1 5 1 3 Connect the BKFD 7009 7009A to the connector on the mother board by putting the lever in the direction of the arrow 1 4 Run the HDD initial set up tool Refer to the section 5 4 5 Remove the BKFD 7009 7009A in the reverse order of the steps 1 through 3 2 5 2 BKFD 7800 HDD extension box n Before powering off the BKFD 7800 it is necessary to prepare for shutdown with the SHUTDOWN button of ...

Page 33: ... V power supply for re adjustment when optional boards are additionally installed etc CNT4 E2 GND terminal The reference GND terminal with respect to 5 V B 3 V _5 V check terminals CN4 H1 232C 1 connector D sub 9 pin connector conforming with the RS 232C signal specifications Connected to the control terminal of the personal computer PC and used for system monitoring and factory adjustment CN5 R3 ...

Page 34: ...REM2 REM2 D5 REM3 REM3 D6 REM4 REM4 D7 REM5 REM5 D8 TERM TERMINAL D24 C1 WD1 indicator green Indicates the status of the CPU 1 A V Turns on when the watch dog is operating D305 L1 WD2 indicator green Indicates the status of the CPU 2 FARAD Turns on when the watch dog is operating D10 to D13 B1 STS1 to STS4 Status indicator green System monitoring status indicator of the CPU 1 A V Turns on when the...

Page 35: ... 5 ROM object select bit 2 This switch is set to OFF during normal operation 2 S3 6 Serial baud rate 3 ON 9600 bps OFF 38400 bps S3 7 Reserved Default S3 8 Reserved Default m 1 An object can be specified when booting from the flash memory However set the switches S3 2 and S3 3 to OFF during normal operation and have been set to OFF when shipped from the factory 2 Refer to section 5 3 PROGRAM INSTA...

Page 36: ...urns on during playback D21 D10 BUF0RAE green Turns on always D26 F10 SEQAE green Turns on always D29 E10 BUF1RAF green Turns on always D31 E10 BUF1RAF green Turns on always D400 A10 REC red Used during production in factory D401 B10 PLAY green Used during production in factory D402 B10 10BIT red Turns on when 10 bit signal is input or output Turns on during normal operation D403 B10 KEY green Tur...

Page 37: ...disk record er is connected to PC personal computer using the HOST SCSI terminal the SCSI ID number of the FDDR 7000 must be set m 1 This SCSI ID switch is effective only when the SCS 15 board is inserted to the slot No 10 2 When the SCS 15 board is inserted to the slot No 8 or 9 this SCSI ID switch does not function The FDDR 7000 operation is not affected by the SCSI ID setting 2 SCSI ID switch s...

Page 38: ...D17 turn on When the maximum number of channels is not set LEDs of the channels which are not set do not turn on Refer to operation manual of FDDR 7000 for the usable number of channels and options required for channel configuration 2 DMA bus operation indication When looking at the illuminating condition of the LEDs it can be judged if the data transfer is performed successfully to the respective...

Page 39: ...rd is correctly installed and operating normally D12 F1 OUT4 yellow Video output channel 4 output module indication Turns on when the SD 46 board is correctly installed and operating normally D14 F1 OUT5 yellow Video output channel 5 output module indication Turns on when the SD 46 board is correctly installed and operating normally D16 F1 OUT6 yellow Video output channel 6 output module indicatio...

Page 40: ...de of power supply unit Check procedures 1 Remove the front panel Refer to the section 1 5 1 2 Confirm that the power supply unit is properly inserted and securely fixed with the four screws 3 Confirm that the required number of BKFD 7009 7009As has been installed in the FDDR 7000 4 Turn ON the power and confirm that the indicator of power supply unit light 5 Connect the digital voltmeter between ...

Page 41: ... 1 2 Confirm that the power supply unit is properly inserted and securely fixed with the four screws 3 Turn ON the power and confirm that the POWER indicators 1 on the CPU 253 board light up 1 POWER indicators D35 D36 and D37 on the CPU 253 board 4 Connect the digital voltmeter between check terminals on CPU 253 board Confirm that the voltage values of each check terminal meet the following specif...

Page 42: ... Remove the front panel Refer to the section 1 5 2 2 Confirm that the power supply unit is properly inserted and securely fixed with the four screws 3 Confirm that the required number of BKFD 7009 7009As has been installed in the BKFD 7800 4 Turn ON the power and confirm that the indicator of power supply unit light 5 Connect the digital voltmeter between check terminals on power supply unit Confi...

Page 43: ...le 68P Cable with Connector SONY P N 1 782 529 11 1 The following solderless contact must be used for the plug AWG 18 to 22 SONY P N 1 566 493 00 AWG 22 to 24 SONY P N 1 564 774 00 AWG 24 to 30 SONY P N 1 564 775 00 n 1 Refer to operation manual supplied with the FDDR 7000 for the system configuration and an example of connection 2 To connect the TIMECODE D sub 25 pin connector of the FDDR 7000 wi...

Page 44: ...e And refer to the following illustration for the pin positions of the connectors 4 2 1 FDDR 7000 Multi channel digital disk recorder VIDEO INPUT 1 6 Serial Digital Component Signnal ACTIVE THRU OUT 270 Mbits second SMPTE259M ITU R BT 656III 800 mV 10 75 Z BNC Left side INPUT Right side ACTIVE THRU OUT VIDEO OUTPUT 1 6 Serial Digital Component Signnal 270 Mbits second SMPTE259M ITU R BT 656III 800...

Page 45: ... GND Ground 6 _ _ 7 RTS Request to send Output 8 CTS Clear to send Input 9 _ _ REME 1 4 RS 422A D sub 9 pin Female Pin No Signal name Function 1 GND Ground 2 TXA Transmitted data _ 3 RXB Received data 4 GND Ground 5 _ _ 6 GND Ground 7 TXB Transmitted data 8 RXA Received data _ 9 GND Ground EXT HDD1 D sub 9 pin Female Pin No Signal name Function 1 GND Ground 2 SI Serial Data Input 3 CLK Clock Signa...

Page 46: ...8 TC3 OUT X TIME CODE OUTPUT 3 SIGNAL 19 TC3 OUT Y TIME CODE OUTPUT 3 SIGNAL _ 20 GND Ground 21 TC4 OUT X TIME CODE OUTPUT 4 SIGNAL 22 TC4 OUT Y TIME CODE OUTPUT 4 SIGNAL _ 23 GND Ground 24 TC5 OUT X TIME CODE OUTPUT 5 SIGNAL 25 TC5 OUT X TIME CODE OUTPUT 5 SIGNAL _ GPI D sub 25 pin Female INPUT x 4 TTL OUTPUT x 6 Open collector Pin No Signal Name Function 1 GND Ground 2 GND Ground 3 GPI IN 2 GPI ...

Page 47: ...und 29 GND Ground 30 GND Ground 31 GND Ground 32 GND Ground 33 GND Ground 34 GND Ground Pin No Signal name Function 35 DB12 Data bus bit 12 36 DB13 Data bus bit 13 37 DB14 Data bus bit 14 38 DB15 Data bus bit 15 39 DBP1 Data bus parity bit 1 40 DB0 Data bus bit 0 41 DB1 Data bus bit 1 42 DB2 Data bus bit 2 43 DB3 Data bus bit 3 44 DB4 Data bus bit 4 45 DB5 Data bus bit 5 46 DB6 Data bus bit 6 47 D...

Page 48: ...0 GND Ground 31 GND Ground 32 GND Ground 33 GND Ground 34 GND Ground Pin No Signal name Function 35 DB12 Data bus bit 12 36 DB13 Data bus bit 13 37 DB14 Data bus bit 14 38 DB15 Data bus bit 15 39 DBP1 Data bus parity bit 1 40 DB0 Data bus bit 0 41 DB1 Data bus bit 1 42 DB2 Data bus bit 2 43 DB3 Data bus bit 3 44 DB4 Data bus bit 4 45 DB5 Data bus bit 5 46 DB6 Data bus bit 6 47 DB7 Data bus bit 7 4...

Page 49: ...EW PREVIOUS BOX1 D sub 9 pin Female Pin No Signal name Function 1 GND Ground 2 SI Serial Data Input 3 CLK Clock Signal 4 SO Serial Data Input 5 RESET RESET Signal 6 GND Ground 7 ENABLE Enable Signal 8 _ _ 9 _ _ NEXT BOX D sub 9 pin Female Pin No Signal name Function 1 GND Ground 2 SI Serial Data Input 3 CLK Clock Signal 4 SO Serial Data Input 5 RESET RESET Signal 6 GND Ground 7 ENABLE Enable Signa...

Page 50: ...0 GND Ground 31 GND Ground 32 GND Ground 33 GND Ground 34 GND Ground Pin No Signal name Function 35 DB12 Data bus bit 12 36 DB13 Data bus bit 13 37 DB14 Data bus bit 14 38 DB15 Data bus bit 15 39 DBP1 Data bus parity bit 1 40 DB0 Data bus bit 0 41 DB1 Data bus bit 1 42 DB2 Data bus bit 2 43 DB3 Data bus bit 3 44 DB4 Data bus bit 4 45 DB5 Data bus bit 5 46 DB6 Data bus bit 6 47 DB7 Data bus bit 7 4...

Page 51: ...h of all BKFD 7800s 2 Turn on the POWER switch of FDDR 7000 Multi channel digital disk Recorder 3 While the system is preparing for starting up the SYSTEM indicators of FDDR 7000 and BKFD 7800 are turned off When the system completes the startup preparation the SYSTEM indicators turn on The time required for startup preparation of a system changes depending upon the number of BKFD 7009 7009A HDD u...

Page 52: ...er is used for the other purposes than the FARAD system control take the following procedure after quitting the Operation Software GUI only of the FARAD system 2 Pressing the SHUTDOWN switch on the front of FDDR 7000 This is the preparation to shut down the FARAD system 3 Wait until the SYSTEM indicator of FDDR 7000 is turned off and tehn release the SHUTDOWN switch 4 After confirming that the SYS...

Page 53: ...Removal of Exterior Parts Procedure 1 Set the switches DIP on the CPU 253 board as follows Set S3 SW1 1 to the ON position Set all of the switches from S3 SW1 2 to S3 SW1 8 to the OFF positions Set S301 SW2 1 to the ON position Set all of the switches from S301 SW2 2 to S301 SW2 8 to the OFF positions indicate switch name Side A Component side 2 Turn on the POWER switch of the FDDR 7000 n The Oper...

Page 54: ...e BZFD 7020 Press Quit to stop installation 8 To start installation select by clicking a FDDR 7000 to which you want to install the operating software from window Click Install Press Quit to stop installation If the switches DIP on the CPU 253 board have not been set yet Running appears on the version portion of the column n If you attempt to install the Operation Software in the FDDR 7000 while R...

Page 55: ...owing ha0 Number of the SCSI host adapter connected d5 The ID number on the SCSI bus SCSI ID is set to 6 l0 The logical unit number This number is always 0 9 The Operation Software 1 2 and 2 2 are installed The progress of installation is displayed as a percentage 10 When installation is complete the menu returns to step 8 To stop installation click Quit on window of step 8 11 When installation is...

Page 56: ...is performed Be sure to make a backup of the data to a VCR Video Cassette Recorder or other media before perform ing the resource setup 5 4 1 When One FDDR 7000 is Connected to the Host Computer 1 Start up the system n Since the resource has not been set yet a system malfunction is detected and the SYSTEM indicator of the FDDR 7000 flashes However the resource can be set using the initial setup to...

Page 57: ...the system n Since the resource has not been set yet a system malfunction is detected and the SYSTEM indicator of the FDDR 7000 flashes However the resource can be set using the initial setup tool 2 Start up Windows NT 3 Insert the CD R supplied with the operating software BZFD 7020 into the CD ROM drive of the personal computer 4 Start up the command prompt in Windows NT 5 Change the current dire...

Page 58: ...wn in step 8 of the procedure for installing the operating software Example faradres h d ha0d6l0 5 5 2 How to Use the Initial Setup Tool 1 Start up the system 2 Start up Windows NT 3 Insert a CD R into the CD ROM drive of the personal computer 4 Start up the command prompt in Windows NT 5 Change the current directory from the Windows NT root directory to the CD R s Tool directory 6 Enter faradres ...

Page 59: ...result in loss of data To avert this danger when restoring especially important data all data should be played back and backed up to a VCR before using the restoration tool Connecting the BNC cable On the rear panel of the FDDR 7000 connect the VIDEO OUTPUT 1 connector to the VIDEO INPUT 2 connector with a BNC cable There is no need to remove any cables connected to the VIDEO INPUT 1 VIDEO OUTPUT ...

Page 60: ...es Settings Enable Send line ends with line feeds Enable Echo typed characters locally 5 6 3 Starting the System Power the FDDR 7000 system on After the FDDR 7000 system has started start the host computer Starting the restoration tool From Windows NT execute the Restore Restore bat batch file on the FDDR 7000 Software Version 1 02 CD ROM The restoration tool starts After about 3 minutes of prepar...

Page 61: ...ing disk is restored requiring less time If only the disk at the front of the unit was replaced enter 1 and press the return key The message is repeated if you enter an incorrect number but entering any characters other than numbers has the same effect as simply pressing the return key the whole unit is restored Example Message displayed when only the return key is pressed Restoring data in all di...

Page 62: ...ttempt is made to restore the data from the position immediately before that where the trouble occurred Data restoration failed Retrying However after restoration fails 5 times no further attempts are made to restore the data in the affected section The section is skipped and restoration continues with the following sections Data restoration failed 5 times Skipping the broken part In this case the...

Page 63: ... 5 25V Earth Ground The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described i...

Page 64: ...Printed in Japan Sony Corporation 1998 9 16 Broadcasting Professional Systems Company 1997 BKFD 7009 7009A SY BKFD 7800 SY FDDR 7000 SY J E 3 193 259 02 ...