5-71
H
t
CH1
CH1
CH2
CH2
magnified
H
t
CH1
CH1
CH2
CH2
magnified
25. Component E-E CR Signal Delay Adjustment
(VD-28 Board)
Mode
E-E
Signal
Color bar (CAMERA input) (Note1)
Measurement Point
CH1: COMPONENT OUTPUT Y
terminal (75
Ω
terminated)
CH2: COMPONENT OUTPUT R-Y
terminal (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
99
Specified Value
t = 0 ± 20 nsec
Note1:
Set “CAMERA” mode with INPUT SELECT switch
Note2:
After this adjustment, check that the specified value of
“Component E-E CR Signal Level Adjustment” is
satisfied.
If not satisfied, perform “Component E-E CR Signal
Level Adjustment”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: E, address: 99, change the data and adjust the
time difference (t) between the boundary of green and magenta
on Y signal and CR signal, that to the specified value.
3) Press the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
For PAL model
For NTSC model
Fig. 5-3-31