H
15. Playback CR Signal Level Adjustment with 7.5%
Setup (VD-28 Board) (DSR-50)
Mode
Playback
Signal
Arbitrary
Measurement Point
COMPONENT OUTPUT R-Y
terminal (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
C4
Specified Value
A = 700 ± 10 mVp-p
Note:
Perform this adjustment after inserting and playing a tape
into the set and setting “SETUP” for “VIDEO LVL” of
the “VIDEO SET” menu to 7.5%.
After the adjustment finished, return “SETUP” to 0%.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 0C, set data: 01, and press the PAUSE
button of the adjustment remote commander.
3) Select page: E, address: C4, change the data and adjust the
component CR signal level (A) to the specified value.
4) Press the PAUSE button of the adjustment remote commander.
5) Select page: 3, address: 0C, set data: 00, and press the PAUSE
button.
6) Select page: 0, address: 01, and set data: 00.
16. Playback CB Signal Level Adjustment with 7.5%
Setup (VD-28 Board) (DSR-50)
Mode
Playback
Signal
Arbitrary
Measurement Point
COMPONENT OUTPUT B-Y
terminal (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
C3
Specified Value
A = 700 ± 10 mVp-p
Note:
Perform this adjustment after inserting and playing a tape
into the set and setting “SETUP” for “VIDEO LVL” of
the “VIDEO SET” menu to 7.5%.
After the adjustment finished, return “SETUP” to 0%.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 0C, set data: 01, and press the PAUSE
button of the adjustment remote commander.
3) Select page: E, address: C3, change the data and adjust the
component CB signal level (A) to the specified value.
4) Press the PAUSE button of the adjustment remote commander.
5) Select page: 3, address: 0C, set data: 00, and press the PAUSE
button.
6) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-21
Fig. 5-3-22