5-37
5.
Record of Use Check
Page E
Address D0 to E3
Using method:
1) The record of use data is displayed at page: E, addresses: D0
to E3.
Note:
When the drum was replaced, initialize the drum rotation
counted time.
Initializing method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: E, address: D0, set data: 00, and press the PAUSE
button.
3) Select address: D1 and E3 and set data “00” into them in the
same way as in address: D0.
4) Select page: 0, address: 01, and set data: 00.
Function
OPRATION 1
Lower two digits
Higher two digits
DRUM RUN 1
Lower two digits
Higher two digits
TAPE RUN 1
Lower two digits
Higher two digits
THREADING 1
Lower two digits
Higher two digits
CHECK SUM 1
Lower two digits
Higher two digits
OPRATION 2
Lower two digits
Higher two digits
DRUM RUN 2
Lower two digits
Higher two digits
TAPE RUN 2
Lower two digits
Higher two digits
THREADING 2
Lower two digits
Higher two digits
CHECK SUM 2
Lower two digits
Higher two digits
Address
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
Remark
The cumulative total hours of operating time is displayed.
The cumulative total hours of drum rotation with tape threaded is displayed.
The cumulative total hours of tape running time is displayed.
The cumulative number of tape unthreading operations is displayed.
The cumulative total hours of operating time is displayed.
The cumulative total hours of drum rotation with tape threaded is displayed.
The cumulative total hours of tape running time is displayed.
The cumulative number of tape unthreading operations is displayed.