5-40
2-3.
SERVICE MODE
1.
Setting the Test Mode
Page D
Address 10
Data
Function
00
Normal
01
Forced CAMERA mode power ON
02
Forced PLAY mode power ON
03
Forced MOVIE mode power ON
• Before setting the data, select page: 0, address: 01, and set data:
01.
• For page D, the data set is recorded in the non-volatile memory
by pressing the PAUSE button of the adjusting remote com-
mander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data
of this address to “00”, and press the PAUSE button of the ad-
justing remote commander.
Select page: 0, address: 01, and set data: 00.
2.
Bit Value Discrimination
Bit values must be discriminated using the display data of the ad-
justing remote commander for following items. Use the table be-
low to discriminate if the bit value is “1” or “0”.
Display on the
Bit values
Adjusting
bit3
bit2
bit1
bit0
remote
or
or
or
or
commander
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A (
A
)
1
0
1
0
B (
b
)
1
0
1
1
C (
c
)
1
1
0
0
D (
d
)
1
1
0
1
E (
E
)
1
1
1
0
F (
F
)
1
1
1
1
Example:
If “8E” is displayed on the adjusting remote com-
mander, the bit values for bit7 to bit4 are shown in the
A
column, and the bit values for bit3 to bit0 are shown
in the
B
column.
0
:
00
:
00
Page
bit7 to bit4 discrimination
bit3 to bit0 discrimination
Address
Display on the adjustilng remote commander
B
A
3.
Mode Dial Check (1)
Page 2
Address 94
Data
Function
00 to 14
MOVIE
15 to 3D
TWILIGHT
3E to 67
CAMERA
Using method:
1) Select page: 2, address: 94.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.
4. Mode Dial Check (2)
Page 2
Address 80, 86
Address
Bit
Function
When bit
When bit
value=1
value=0
80
1
PLAY
others
PLAY
86
6
SET UP
others
SET UP
Using method:
1) Select page: 2, address: 80 and 86.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.
5.
Switch Check (1)
Page 2
Address 80
Bit
Function
When bit value=1 When bit value=0
0
POWER SW
OFF
ON
1
PLAY
others
PLAY
(Mode Dial)
2
3
SHUTTR SW
OFF
ON
(CONTROL SWITCH
BLOCK)
4
XSHUTTER LOCK SW
OFF
ON
(CONTROL SWITCH
BLOCK)
5
MEMORY STICK
OUT
IN
IN SW (MS Socket)
Using method:
1) Select page: 2, address: 80.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.