5-15
1.
HALL Adjustment
For detecting the position of lens iris, adjust the HALL AMP gain
and offset.
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 2)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
2E, 2F, 34, 35
Specified Value
10 to 18 during IRIS OPEN
75 to 7D during IRIS CLOSE
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
The right 2 digits of the page: 1 displayed data of the
adjusting remote commander.
1:00:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
94
14
4
6
95
79
5
6
01
6D
Press PAUSE button. (Note 3)
6
6
02
Check the data changes to “01”.
7
6
01
00
Press PAUSE button.
8
0
03
03
9
6
01
01
Press PAUSE button.
10
1
Check that the displayed data
(Note 2)
during IRIS OPEN satisfies
the specified value.
11
6
01
03
Press PAUSE button.
12
1
Check that the displayed data
(Note 2) during IRIS CLOSE
satisfies the specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 2E, 2F, 34 and 35.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
94
00
4
6
95
00
5
Release the data setting
performed at step 2.
(Refer to page 5-14)
6
0
01
00