5-25
13. Color Reproduction Check
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75
Ω
terminated)
Measuring Instrument
Vectorscope
Specified Value
All color luminance points
should settle within each color
reproduction frame.
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
10
01
12
E
52
Note down the data.
13
E
52
08
Press PAUSE button.
14
6
01
0F
Press PAUSE button.
15
6
12
80
16
Wait for 1 second.
17
6
12
00
18
Wait for 2 seconds.
19
Check the each color
luminance point is each color
reproduction frame.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
10
00
3
6
2C
00
4
6
92
00
5
6
93
00
6
E
52
Set the data noted down at step
12, and press PAUSE button.
7
Release the data setting
performed at step 2 . (Refer
to page 5-14)
8
0
01
00
Fig. 5-1-17
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position