6-21
DSC-F828
11-2.
Linear Matrix and AWB Adjustment
This adjustment does the following adjustment items automatically.
Linear matrix adjustment
Compensate the dispersion of the linear matrix vale of the
CCD imager.
AWB 3200K/5800K (Mon) standard data input
Acquire the white balance standard data at 3200K and 5800K
in monitoring mode.
AWB 3200K/5800K (Cap) standard data input
Acquire the white balance standard data at 3200K and 5800K
in capture mode.
Mode
STILL (P AUTO) (
P
)
Subject
9 colors chart (PTB-1450)
(Standard picture frame)
About 6cm from the front of the lens
Adjustment Page
6E
Adjustment Address
80 to 9F (Linear matrix adjustment)
04 to 21, 24 to 49 (AWB 3200K/
5800K standard data input)
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
1)
Install the camera for adjustment.
2)
Check that “1. Data Setting during Camera System Adjustments”
is performed.
3)
Set up the switches of the reference camera as above-mentioned.
4)
Shoot the 9 colors chart with the standard picture frame. (Refer
to “6. Picture Frame Setting (PTB-1450)”.
5)
Adjust the focus..
6)
Start the F828 C1 MATRIX ADJ on the PC.
7)
Click [Connect] on the F828 C1 MATRIX Adjustment screen.
8)
Click [Linear Matrix and AWB Adjustment] on the F828 C1
MATRIX Adjustment screen.
Fig. 6-1-22.
9)
The following adjustments are performed automatically.
Linear matrix adjustment
AWB 3200K/5800K (Mon) standard data input
AWB 3200K/5800K (Cap) standard data input
Note:
When the “Framing check” message is displayed, correct the picture
frame, and repeat from step 7).
When the “File C:\ProgramFiles\Sony\F828C1MATRIX\
GodRawData.CSV can not be open” message is displayed, the
reference data file (GodRawData.CSV) for the liner matrix
adjustment is not in the inside of the PC. Therefore, perform “11-1.
Preparation (Get Reference Data)”.
Fig. 6-1-23.
Fig. 6-1-24.
10) When the “Completion of adjustment” message is displayed.
Click the [OK] button.
Fig. 6-1-25.
11) If finish the camera system adjustments, release the data setting.