6-28
DSC-F828
17. Strobe Adjustment
Adjust the light level and white balance when the strobe light flashes.
Mode
STILL (P AUTO) (
P
)
Subject
Background paper (J-2501-130-A)
(50cm from the front of the lens)
Measurement Point
Data of page 6F, address: DC
Measuring Instrument
Data of page 6E, address: 4F
Adjustment Page
6F
6E
Adjustment Address
D8 to EF
72 to 75
Specified Value1
03 to 09
Specified Value2
00
Note1:
Perform this adjustment in the dark room or use the flash
adjustment box.
Note2:
Any light other than the strobe light should not light up the plate.
Note3:
After the power is turned on, this adjustment can be done only
once.
Note4:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
FLASH ......................................................................... OPEN
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
60
2C
01
Set the data.
3
60
92
FF
Set the data.
4
60
93
FF
Set the data.
5
60
6C
01
Set the data.
6
60
01
79
Set the data.
7
Wait for 5 sec.
8
60
07
Read the data, and check it is “01”.
9
6E
4F
FF
Set the data.
10
60
01
B9
Set the data.
11
Check the flashing.
12
60
02
Read the data, and check it is
“01”. (Note5)
13
6F
D8
Read the data, and check it is “00”.
14
60
01
00
Set the data.
15
Wait for 5 sec.
16
60
ED
Read the data, and check it is “02”.
17
Wait for 1 sec.
18
60
01
E7
Set the data.
19
Check the flashing.
20
60
02
Read the data, and check it is “01”.
21
6F
D8
Read the data, and check it is “00”.
22
6F
DC
Read the data, and check it
satisfies the specified value 1.
23
6E
4F
Read the data, and check it
satisfies the specified value 2.
Note5:
The adjustment data will be automatically input to page: 6F,
address: D8 to EF, and to page: 6E, address: 72 to 75.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Set the data.
2
60
2C
00
Set the data.
3
60
6C
00
Set the data.
4
60
92
00
Set the data.
5
60
93
00
Set the data.
6
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)