6-29
DSC-F828
18. AF Laser Output Adjustment
Adjust the AF laser output power.
Mode
STILL (P AUTO) (
P
)
Subject
Background paper (J-2501-130-A).
(50cm from the front of the lens)
Measurement Point
Data of page 6F, address: 13
Measuring Instrument
Adjustment Page
6F
Adjustment Address
10 to 16
Specified Value
00
Note1:
Perform this adjustment in the dark room or use the flash
adjustment box.
Note2:
Any light other than the strobe light should not light up the plate.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
6F
10
20
Set the data.
3
6F
15
48
Set the data.
4
60
01
AF
Write the data.
5
Check that the AF laser is lit.
6
Wait for 8 sec.
7
60
02
Read the data, and check it is
“01”. (Note3)
8
6F
13
Read the data, and check it
satisfies the specified value 1.
Note3:
The adjustment data will be automatically input to page: 6F,
address: 10 to 16.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Write the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during