6-19
DSC-F828
10. Light Value Adjustment
Adjust the standard LV value.
Mode
STILL (P AUTO) (
P
)
Subject
Clear chart (PTB-1450/PTB-450)
(Standard picture frame)
Measurement Point
Data of page: 10, address: 0C, 0D
Measuring Instrument
Data of page: 6F, address: 65
Adjustment Page
6F
Adjustment Address
65 to 67
Specified value1
0FE0 to 1020
Specified value2
40 to 60
Note1:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Check the picture frame. If
deviated, perform “5. or 6.
Picture Frame Setting”.
3
60
01
0D
Set the data.
4
Wait for 2 sec.
5
60
02
Read the data, and check it is
“01”. (Note2)
6
10
0C
Read the data, and this data is
named D
0C
.
7
10
0D
Read the data, and this data is
named D
0D
.
8
Calculate D
LV
using the
following equation
(Hexadecimal calculation)
D
LV
= D
0C
×
100 + D
0D
10
Check that D
LV
satisfies the
specified value1.
11
6F
65
Read the data, and check it
satisfies the specified value2.
Note2:
The adjustment data will be automatically input to page: 6F,
address: 65 to 67.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Set the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)