6-16
DSC-F828
6. Picture Frame Setting (PTB-1450)
Mode
STILL (P AUTO) (
P
)
Subject
9 colors chart and clear chart
(Standard picture frame) (Note1)
About 6cm from the front of the lens
Measurement Point
Video terminal of A/V OUT jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=B/3
Note1
: Check that the transparent window is in the lower right.
Switch setting:
ZOOM .................................................................... WIDE end
Setting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Shoot the 9 colors chart with
the zoom WIDE end.
3
Adjust the direction and distance
between the pattern box and
camera, and set the picture
frame to the specified position.
4
Adjust the focus.
5
Remove the 9 colors chart and
set the clear chart.
6
Check that the whole of the
screen is white. If not, adjust the
direction and distance slightly.
7
10
44
Read the data, and this data
named YH.
8
10
45
Read the data, and this data
named YL.
9
Perform the following
adjustments.
How to reset the focus when it deviated:
If the focus deviated due to some reason reset it in the following
method.
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
60
90
00
Set the data.
3
60
91
00
Set the data.
4
60
92
YL
Set the data. (Note2)
5
60
93
YH
Set the data. (Note2)
6
60
01
79
Set the data.
7
Wait until the movement of the
lens stops.
8
60
07
Read the data, and check it is “01”.
9
60
01
00
Set the data.
Note2
: YH and YL are the data read in the “Setting method”.
Check on an oscilloscope
1. Horizontal period
Fig. 6-1-13.
2. Vertical period
Fig. 6-1-14.
Check on the monitor TV (Underscanned mode)
on the LCD screen
Fig. 6-1-15.
B
A
A
A = B
C
C
B
V
C =
B
3
A
A = B
C
C
C14 : Filter for AWB 5800K adjustment
Effective picture frame
Transparent window
White
Green
Yellow
W14
Red
Magenta
Cyan
Blue
B
C14
C =
B
3
A
2
B
A