6-32
DSC-F828
3. VCO Adjustment (SY-096 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
PLAY (
)
Subject
Arbitrary
Measurement Point
Data of page: 80, address: 02
Measuring Instrument
Adjustment Page
8F
Adjustment Address
73
Specified Value
01
Note1:
A memory stick must be inserted.
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during EVF System
Adjustments” is performed.
2
8F
84
2F
Set the data.
3
80
00
00
Set the data.
4
80
02
00
Set the data.
5
80
01
80
Set the data.
6
80
00
01
Set the data.
7
Wait for 1 sec.
8
80
02
Read the data, and check it is
“01”. (Note2)
9
Wait for 1 sec.
10
If finish the EVF system
adjustments, release the data
setting.
(See “1. Data Setting during
EVF System Adjustments”.)
Note2:
If the data is other than “01”, adjustment has errors. See the
following table.
4. Bright Adjustment (SY-096 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
PLAY (
)
Subject
Arbitrary
Measurement Point
Data of page: 80, address: 02
Measuring Instrument
Adjustment Page
8F
Adjustment Address
75
Specified Value
01
Note1:
A memory stick must be inserted.
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during EVF System
Adjustments” is performed.
2
8F
88
9F
Set the data.
3
80
00
00
Set the data.
4
80
02
00
Set the data.
5
80
01
80
Set the data.
6
80
00
03
Set the data.
7
Wait for 1 sec.
8
80
02
Read the data, and check it is
“01”. (Note2)
9
Wait for 1 sec.
10
If finish the EVF system
adjustments, release the data
setting.
(See “1. Data Setting during
EVF System Adjustments”.)
Note2:
If the data is other than “01”, adjustment has errors. See the
following table.
Data of page: 80,
address: 02
01
10
20
30
40
50
Contents of adjustment error
Normally finished
Reached an upper limit
Reached a lower limit
Time out
Out of adjustment range
Adjustment is impossible
Data of page: 80,
address: 02
01
10
20
30
40
50
Contents of adjustment error
Normally finished
Reached an upper limit
Reached a lower limit
Time out
Out of adjustment range
Adjustment is impossible