3-16
CCU-700A
CCU-700AP
3-3. Video Signal System Adjustment
3-3-23. WF 1 OUT Level Adjustment
Rank
:
B
Equipment
:
Waveform monitor
To be extended
:
VA-156 board
Preparation
• Connect the RCP-74x to the CCU.
• BARS button/RCP-74x
→
“ON”
• MONITOR SELECT button/RCP-74x
→
“ENC”
• WF 1 OUT connector/CCU rear panel
→
75
Z
Terminated
Test point
:
WF 1 OUT connector/CCU rear panel
Adjusting point
:
1
RV761 (WF1 VIDEO LEVEL)/
VA-156 board
Specification
:
[For NTSC] A = 100
±
1 IRE
[For PAL]
A = 700
±
7 mV
3-3-24. PIX 1 OUT Level Adjustment
Rank
:
B
Equipment
:
Waveform monitor
To be extended
:
VA-156 board
Preparation
• BARS button/RCP-74x
→
“ON”
• MONITOR SELECT button/RCP-74x
→
“ENC”
• PIX 1 OUT connector/CCU rear panel
→
75
Z
Terminated
Test point
:
PIX 1 OUT connector/CCU rear
panel
Adjusting point
:
1
RV931 (PIX1 VIDEO LEVEL)/
VA-156 board
Specification
:
[For NTSC] A = 100
±
1 IRE
[For PAL]
A = 700
±
7 mV
Note:
After the adjustment, set as follows.
• Connect the MSU-700 to the CCU.
A
A
[For NTSC]
[For PAL]
A
A
[For NTSC]
[For PAL]