3-25
CCU-700 A
CCU-700AP
6 pulses
V
50%
T
3-4-6. Sample Pulse V Gate Width
Adjustment
Rank
:
B
Equipment
:
Oscilloscope
To be extended
:
DM-94 board
Test point
:
TP7 (GND: E2)/DM-94 board
Adjusting point
:
1
RV3 (SAMPLE GATE)/DM-94
board
Adjustment Procedure
• Confirm that the sample pulses have six pulses in both
odd and even fields.
If not met, adjust
1
RV3 (SAMPLE GATE)/DM-94
board so that the sample pulses have six pulses in both
odd and even fields.
3-4-5. Sample Pulse Width Adjustment
Rank
:
B
Equipment
:
Oscilloscope
To be extended
:
DM-94 board
Test point
:
TP7 (GND: E2)/DM-94 board
Adjusting point
:
1
RV4 (SAMPLE S/H)/DM-94
board
Specification
:
T = 40.0
±
2.0
µ
s
3-4. Y Cable Compensation System Adjustment