3-7
PFM-500A3WE/500A3WG/500A3WU/510A2WE/510A2WG/510A2WU
a)
ORIGINAL DATA SELECT
Menu Structure
Select the source data that is used for editing. Then the selected source data is
copied to the Editing RAM.
(1) CURRENT DATA SELECT
When an editing is performed using the signal that is being inputted at present is
selected as the source data, move the cursor to this item and press ENTER. The
selected data is copied to the Editing RAM.
(2) FORMAT TABLE : PROGRAM 1
When an editing is performed using the signal that is already stored in the preset
area is selected as the source data, move the cursor to this item and press
ENTER. Select the desired area from Table 1 by pressing the
+
/
_
keys. The
selected data is copied to the Editing RAM.
(3) - ORIGINAL FORMAT -
Frequency of the signal that is selected as the source data in step (1) or (2) is
displayed.
Use the frequency data as the fundamental information when selecting a source
data.
(4) EDIT MODE
When the signal that is being inputted at present is selected as the source data,
the message DIRECT appears. When the signal that is already stored in the
preset area is selected as the source data, the message TABLE appears.
Note : The editing items that can be editing here are different in the DIRECT mode and the TABLE mode.
Refer to the next sub-section “b) DATA EDIT” for the editing items.
< When DIRECT mode is used for editing >
… The DIRECT mode is used when editing is performed while watching the
picture on screen in the case that the specifications of the signal are not known. …
When DIRECT mode is selected, select the desired adjustment item referring to
the next sub-section “b) DATA EDIT” by pressing the
+
/
_
keys. Press the EN-
TER key. Then the result of data adjustment is reflected on the display screen.
(Pressing the MENU key returns to the previous menu display.)
However, the three adjustment items H FREQUENCY, V FREQUENCY and
SYNC POL cannot be changed by the menu operation.
< When TABLE mode is used for editing >
… The TABLE mode is used when the specifications of the signal to edit are
already known. …
All adjustment items adjusted by the menu but result of adjustment is not
reflected on the actual picture. Data can be edited only.
ORIGINAL DATA SELECT
CURRENT DATA SELECT
FORMAT TABLE
- ORIGINAL FORMAT -
H FREQUENCY
V FREQUENCY
SYNC POL (H/V)
EDIT MODE
: PROGRAM1
: 31.47 [kHz]
: 60.00 [Hz]
: NEGE/NEGA
: DIRECT
(1) The signal that is being inputted at present
is selected as the source data.
(2) The signal that is already stored in the preset
area is selected as the source data.
(3) Frequency of the signal that is selected
as the source data is displayed.
(4) Type of the signal that is selected as the
source data is displayed.