Displaying parameter values
The numerical values of the parameters appear in the menu.
Numerical parameter values
a) 600 corresponds to the full width of the screen.
b) 300 corresponds to the full height of the screen.
c) 100 corresponds to 360 degrees.
d) For SPHERE, the Angle and the Radius parameter do not function.
Resetting the parameters to their initial values
• To reset all of the parameters, hold down the INITIAL button, and press
the PATTERN ADJ button.
The initial values of the parameters are for an unmodified image
occupying the whole screen.
• To reset all of the parameters on a particular page, hold down the
INITIAL button, and press the PAGE button.
• To reset a particular parameter only, press the corresponding function
button while holding down the INITIAL button.
User Program Effects
Parameter
Function
Value range
Default
Loc-X
Movement along x-axis
–800 to +800
a)
0
Loc-Y
Movement along y-axis
–600 to +600
b)
0
Loc-Z
Magnification
0 to 200
100
KfDur
Key frame duration
1 to 100
50
Rot-X
Rotation about the x-axis
–400 to +400
c)
0
Rot-Y
Rotation about the y-axis
–400 to +400
c)
0
Rot-Z
Rotation about the z-axis
–400 to +400
c)
0
Pers
Perspective
0 to 400
200
Angle
Direction of folding
–100 to +100
c)
20
Offset
Degree of modification
0 to 200
0
Rot-Z
Rotation about the z-axis
–400 to +400
c)
0
Radius
Radius
0 to 100
0
FORM
Type of modification
TURN, ROLL, SPHERE
d)
TURN
Chapter 4 Advanced Operations
Chapter 4 Advanced Operations
4-9
About the key frame duration
The KfDur value (key frame duration) for key frame n corresponds to the
interval between key frame n and key frame n+1. Therefore, if the settings
are as follows:
Key frame 1
... not effective
Key frame 2
... KfDur 100
Key frame 3
... KfDur 50
Key frame 4
... KfDur 50
The interval between key frames 1 and 2 is twice that between the other
pairs of frames. For example, if the transition duration is set to 100 frames,
the transition will proceed as follows:
Key frame 4
t
3
... 25 frames
Key frame 3
t
2
... 25 frames
Key frame 2
t
1
... 50 frames
Setting the type of interpolation
When executing the effect, using the F1 button in the menu, you can set
the type of interpolation between key frames as follows:
Lin:
linear interpolation
S-Lin:
S-curve interpolation
Spln:
spline interpolation
V-Spln:
parameterized spline interpolation
If you select V-Spln, with the F2(Tens) knob you can adjust the tension of
the spline curve in the range –100 to +100. This controls the smoothness,