![Sonifex S0 v2 Handbook Download Page 34](http://html1.mh-extra.com/html/sonifex/s0-v2/s0-v2_handbook_1321165034.webp)
24
3 Configuration Options
The Restore Defaults button returns the configuration
options on the connected S0 v2 to factory default settings.
The Firmware Update function allows the S0 v2 firmware
to be regularly updated with new features and bug fixes.
New firmware releases will be made available on the
Sonifex website. To update the firmware, press the Update
button and select the firmware file. The update only takes
a few minutes and the process can be monitored on the
progress bar on SCi and the meter display on the S0 v2,
which gradually changes from fully illuminated to off.
When the update is complete, the S0 v2 will automatically
reboot and SCi will reconnect and show the new firmware
version number.
The S0 v2 is designed to power up in the same state it
was in when power was removed. It is possible to clear
these saved settings so the mixer starts with all buttons
and routing switched off, except for those enabled by the
default configuration options:
1.
Ensure all faders are closed.
2.
Press and hold the Monitor EXT1, Monitor AUTO
CUE/PFL, Presenter AUTO CUE/PFL and Guest AUTO
CUE/PFL buttons.
3.
Press Reset Switch as shown in image below. A
single sweep on the LED meters indicates that the
saved states are being reset. The buttons can be
released.
4.
A dual sweep on the LED meters indicates return to
normal operation.
Fig 3-4: SCI Info & Updates Screen.