23
Configuration Options 3
These settings control the operation of the AUTO CUE/
PFL button modes and the audio meter display type. This
section also controls the USB Audio input CUE/PFL mode.
This determines whether the USB Audio input channel is
automatically routed to the monitor section. If enabled,
the USB Audio input will be available on any of the
monitor channels that have the AUTO CUE/PFL function
enabled.
To store the configuration option settings onto the
connected S0 v2, press the Save Settings button. The S0 v2
will then restart with the new option values.
The current configuration option settings on the
connected S0 v2 can be reloaded into SCi at any point by
pressing the Reload Settings button. Any changes made
since the settings were last reloaded or saved will be lost.
The last tab, Info & Updates allows the current
configuration settings in SCI to be saved to a file on the
computer. This makes it easier to configure multiple
units with the same configuration settings. First select
the required settings in the Channel and Monitor
Configuration tabs, and then press the Save Configuration
button. A save dialog will be displayed allowing the
filename to be entered. Upon pressing the save button
the current settings will be stored in the selected file.
These settings can then be loaded whilst connected to a
different unit by pressing the Load Configuration button.
The settings stored in the file will be loaded into SCI and
automatically uploaded into the connected S0 v2.
Fig 3-3: SCI Monitor Configuration Screen.