4.12 SELV/PELV appliances test
The test consists in checking whether the source generates extra-low voltage within limits.
Press
SELV/PELV
.
Before starting the measurement, similarly to
sec. 4.2
, following parameters must be set:
test dura-
tion
and
limits
: lower and upper.
Using the 1.5 m double-wire test lead, connect the low-voltage plug of the tested voltage
source to the tester's
T1
socket. Then connect the voltage source to power.
Press
START
.
Upon completing the measurement read the result. You can finish the
test before the defined test time duration by pressing
STOP
.
Positive test result:
LOWER LIMIT
≤ I
Δ
≤ UPPER LIMIT
Negative test result:
I
Δ
< LOWER LIMIT
or
I
Δ
> UPPER LIMIT