7
Copyright © 2013 Somfy SAS. All rights reserved.
Video door phone - V600 RTS
EN
Avoid installing the camera facing a light source, images of visitors may be impaired.
We recommend that silicon sealant is applied between the rain shield and the wall/pillar (but not below the rain shield) and that the door station
is fitted at a height of approximately 1.60 m.
INSTallINg ThE dooR STaTIoN aNd adjuSTINg ThE CamERa'S VIEwINg
aNglE
[1].
Feed all the cables (monitor, gate and electric door-opener/lock) into the rain shield.
[2].
Fix the rain shield to the wall/pillar.
[3].
Connect: - the monitor cable to terminals M+ and M- of the door station:
M+ of the monitor to M+ of the door station
M- of the monitor to M- of the door station
- the motorisation cable to the dry contact output (COM and NO) of the door station
- the electric door-opener/lock cable to ter and - of the door station.
- the power plug to the + and - terminals of the door station: black wire with white lines to + and all black wire to -.
Note:
To feed the cables into the terminals, use a screwdriver to press on the square with the notch, feed the wires in, then release.
[4].
The fingerprint scanner enables a visitor to control the gate and electric door-opener/lock connected to the door station.
With the dipswitch S1 at the rear of the door station, select the automatic control system to be controlled by the fingerprint scanner:
S1 = OFF: the gate is controlled
S1 = ON: the electric door-opener/lock is controlled
Note:
The door station must be switched off in order to change the position of S1.
[5].
If you wish to change the camera's viewing angle, unscrew the screw at the rear of the door station slightly, move the camera to the desired
position, then retighten the screw while holding it in the chosen position.
[6].
Install the door station in the rain shield.
[7].
Screw the door station to the rain shield using the torx key.
1
2
3
6
7
gate motorisation
cable
monitor
cable
power
supply cable
Electric door-
opener/lock cable
S1
OFF
ON
OFF:
ON:
5
4