Copyright © 2013 Somfy SAS. All rights reserved.
10
Video door phone - V600 RTS
EN
► Clearing one or all of the stored fingerprints
→
Clearing a fingerprint
[1].
Switch to programming mode.
[2].
Enter the 3-figure fingerprint identification number that you wish to clear
into the adjustment remote control.
[3].
Press
*
(star) twice.
The indicator above the scanner turns green. The fingerprint is cleared.
x x x
vert
*
+
*
+
fingerprint no.
#
→
Clearing all the fingerprints
[1].
Switch to programming mode.
[2].
Press
*
(star) then 8 on the adjustment remote control.
The indicator light above the scanner flashes yellow.
[3].
Press 8 on the adjustment remote control twice.
The door station emits a long beep to confirm. All the fingerprints are
cleared.
*
8
+
8
8
+
*
5
+
x
x
+
*
8
+
9
9
+
yellow
yellow
yellow
yellow
red
green
security
level
security
level
►
adjusting the security level
This parameter allows recognition sensitivity to be set for the digital
fingerprints.
The security level can be set from 1 (minimum security level) to 5 (maximum
security level).
We advise you to keep the factory security level settings (set at 3).
Note:
To adjust the security level, the administrator code must not be the
default administrator code (1234).
[1].
Switch to programming mode.
[2].
Press
*
(star) then 5 on the adjustment remote control.
The indicator light above the scanner flashes yellow.
[3].
Enter the figure corresponding to the desired security level twice on the
adjustment remote control.
The door station emits a beep to confirm. The security level is set.
- The door station emits three beeps. The security level has not be altered.
Go back to step [2].
►
Restoring the factory settings
[1].
Switch to programming mode.
[2].
Press
*
(star) then 8 on the adjustment remote control.
The indicator light above the scanner flashes yellow.
[3].
Press 9 on the adjustment remote control twice.
The door station emits a long beep to confirm. The factory settings are
restored:
- all the fingerprints are cleared,
- the default administrator code (1234) is restored.
Exiting programming mode
To exit programming mode, press # on the adjustment remote control.
The indicator turns red.
Note:
Programming mode is exited automatically after 30 seconds of
inactivity.