background image

15

 

Copyright © 2013 Somfy SAS. All rights reserved.

Video door phone - V600 RTS

EN

 

programming a Somfy RTS gate motorisation

Note: 

The monitor can be disconnected from the power supply to carry out this operation.

[1].  

Access the motorisation electronics.

[2].  

Check that the motor is powered on.

[3].  

 Remove the monitor from its mounting bracket.   

 Select a free channel by pressing the channel selection button on the monitor.

[4].  

 On an Axovia 220B or an Elixo Optimo: place the monitor on the target on the motor electronic unit. 

 

Important:  

The right-hand section of the monitor must be placed on the electronic unit target so that the monitor can be correctly detected 

by the motor electronics.

On an Elixo 800/1300/2000, an Elixo 500 230V RTS, an Elixo 500 3S RTS or a Control Box 3S RTS, press the PROG button for 2 seconds.

[5].  

 Briefly press the monitor opening button.

Note:

  To program the monitor on a motorisation other than those described above, refer to the guide for this motorisation.

1   2   3   4

1   2   3   4

1   2   3   4

RADIO

RESET

=
=

RADIO

RESET

=
=

< 0,5s

AXOVIA 220B RTS

ELIXO OPTIMO RTS

ELIXO 800/1300/2000 RTS

CONTROL BOX 3S RTS

ELIXO 500 3S RTS

PROG

2s

PROG

PROG

PROG

PROG

< 0,5s

2s

Add

< 0,5s

ELIXO 500 230V RTS

1   2   3   4

1   2   3   4

1   2   3   4

RADIO

RESET

=
=

RADIO

RESET

=
=

< 0,5s

AXOVIA 220B RTS

ELIXO OPTIMO RTS

ELIXO 800/1300/2000 RTS

CONTROL BOX 3S RTS

ELIXO 500 3S RTS

PROG

2s

PROG

PROG

PROG

PROG

< 0,5s

2s

Add

< 0,5s

ELIXO 500 230V RTS

4

5
6

Note:

   To clear the video entry phone programming on a Somfy gate motorisation, see the motorisation guide.

Summary of Contents for HOME MOTION V600 RTS

Page 1: ...Video door phone V600 RTS EN Installation instructions 1 2 3 4...

Page 2: ...e stored in a safe place throughout the service life of your product Before installation check that this Somfy product is compatible with the associated equipment and accessories This guide describes...

Page 3: ...roduct which is not strictly personal is subject to statutory obligations in particular law no 78 17 of 6 January 1978 according to which the purchaser is responsible for requesting information from t...

Page 4: ...ement of the gate roller shutter or garage door 7 Closed Off button Control for closing the gate roller shutter garage door or for switching lighting off 8 Channel selection button Enables the radio c...

Page 5: ...l fingerprint is already stored to control opening of the gate or to control the electric door opener lock 7 Backlit name tag label Indicates your name on a label 8 Backlit call button Visitors can us...

Page 6: ...wer plug The door station power plug can be installed either inside the house or outside next to the door station You can add a second monitor ref 1841206 to your installation max distance between 2 m...

Page 7: ...in which the wires are connected to the power plug is important Important It is essential to use the power plug provided to supply the monitor Prepare the monitor for connection to the door station by...

Page 8: ...d terminals of the door station black wire with white lines to and all black wire to Note To feed the cables into the terminals use a screwdriver to press on the square with the notch feed the wires i...

Page 9: ...sation see page 11 Connect the door station dry contact output COM and NO to the dry contact input for the motorisation electronics Fitting the name tag 1 Press and push on the left hand side of tag 2...

Page 10: ...a 3 figure fingerprint identification number on the adjustment remote control for example 001 If the indicator light above the scanner turns green this fingerprinting number is available Carry out st...

Page 11: ...o 5 maximum security level We advise you to keep the factory security level settings set at 3 Note To adjust the security level the administrator code must not be the default administrator code 1234 1...

Page 12: ...fy RTS unit The monitor is equipped with a Somfy Radio Technology RTS transmitter It is only compatible with devices equipped with Somfy Radio Technology RTS It is used to control the following Somfy...

Page 13: ...election button on the monitor 4 Press the motor PROG button for 2 seconds button B on a Dexxo Compact RTS The motor s integrated light comes on 5 Briefly press the monitor opening button The motor s...

Page 14: ...on the receiver until the indicator light on the receiver comes on The programming function is activated for 2 minutes 4 Select a free channel by pressing the channel selection button on the monitor...

Page 15: ...ol 3 Press the PROG button on the original control until the roller shutter makes an up and down movement or a series of 3 beeps The programming function is activated for 2 minutes 4 Select a free cha...

Page 16: ...d by the motor electronics On an Elixo 800 1300 2000 an Elixo 500 230V RTS an Elixo 500 3S RTS or a Control Box 3S RTS press the PROG button for 2 seconds 5 Briefly press the monitor opening button No...

Page 17: ...x 234 pixels Max communication time 2 minutes Operating temperature 10 C to 55 C Radio transmitter Frequency 433 42 MHz Power supply 3 V type CR2430 Range 200 m in open space Door station Power supply...

Page 18: ...5 475 0732 81 0 45 475 0922 Jordan Somfy Jordan 962 6 5821615 Kingdom of Saudi Arabia Somfy Saoudi Riyadh 966 1 47 23 203 Jeddah 966 2 69 83 353 Kuwait Somfy Kuwait 00965 4348906 Lebanon Somfy Middle...

Reviews: