EN
Elixo 500 3S RTS
Copyright © 2015 Somfy SAS. All rights reserved
15
Meaning of different parameters
Code Description
Values (bold = default)
Setting
completed
Comments
P01
Complete cycle
operating mode
0: sequential
Each press on the remote control causes the motor to move (initial position: gate
closed) as per the following cycle: open, stop, close, stop, open, etc.
1: sequ timed close
Operation in
automatic closing
mode is only
authorised if the
photoelectric cells
DUH¿WWHG
i.e. P07=1 to 4.
In sequential mode with automatic timed close:
- the gate closes automatically after the time delay programmed
in parameter "
P02
",
- pressing a button on the remote control interrupts the
movement taking place and the timed close (the gate remains
open).
2: semiautomatic
In semiautomatic mode:
- pressing a button on the remote control during opening has no effect,
- pressing a button on the remote control during closing causes it to reopen.
3: automatic
Operation in
automatic closing
mode is only
authorised if the
photoelectric cells
DUH¿WWHG
i.e. P07=1 to 4.
These operating
modes are not
compatible with
remote control using
a TaHoma unit
In automatic closure mode:
- the gate closes automatically after the time delay programmed
in parameter "
P02
",
- pressing a button on the remote control during opening has
no effect,
- pressing a button on the remote control during closing causes
it to reopen,
- pressing a button on the remote control during the closing time
delay restarts the time delay (the gate will close when the new
time delay has elapsed).
,IWKHUHLVDQREVWDFOHLQWKHFHOOVGHWHFWLRQ]RQHWKHJDWHZLOO
not close. It will close once the obstacle is removed.
4: aut cell blocking
After the gate is opened, movement in front of the cells (safe
FORVXUHZLOOFORVHWKHJDWHDIWHUDVKRUWWLPHGHOD\¿[HGDW
seconds).
If there is no movement in front of the cells, the gate will close
automatically after the timed close programmed in parameter
"
P02
".
,IWKHUHLVDQREVWDFOHLQWKHFHOOVGHWHFWLRQ]RQHWKHJDWHZLOO
not close. It will close once the obstacle is removed.
GHDGPDQVFRQWUROZLUH
In wired deadman mode*
- the gate can only be controlled by continuous action on a wired control,
- the radio controls are inactive.
P02
Complete operating
mode automatic timed
closing
0 to 30 ( value x 10 s = time delay
value)
2: 20 s
If value 0 is selected, the gate immediately closes automatically.
ADVANCED PARAMETER SETTING
Navigating the parameter list
Press ...
to...
Access and exit the parameter setting menu
Navigate the parameters and codes list:
.
short press
=
normal scrolling
through individual parameters
.
press and hold
=
rapid scrolling
through parameters
&RQ¿UP
. the parameter selection
. the parameter value
Increase/decrease the value of a parameter
.
short press
=
normal scrolling
through individual parameters
.
press and hold
=
rapid scrolling
through parameters
Parameter value display
If the display is
¿[HG
, the displayed value is the
value selected
for this parameter.
If the display is
ÀDVKLQJ
, the displayed value is the
value selectable
for this parameter.
Press SET to exit the parameter setting menu.
Summary of Contents for Elixo 500 3S RTS
Page 1: ...D811950_03_15 01 2015 ELIXO 500 3S RTS EN Installation instructions TR 0RQWDM N ODYX X FA AR...
Page 2: ......
Page 64: ...FAElixo 500 3S RTS 2 Copyright 2015 Somfy SAS All rights reserved 1 www somfy com...
Page 84: ...ARElixo 500 3S RTS Copyright 2015 Somfy SAS All rights reserved 3 10 30 2 2400484 1 5 50...
Page 87: ......