Description of the various additional devices
Photoelectric cells (Fig. 1)
Three types of connection are possible:
A: Without autotest:
programme parameter "P07" = 1.
B: With autotest:
programme parameter "P07" = 3.
Allows an automatic test to be carried out to check the operation of the photoelectric cells each time the gate moves.
If the operating test result is negative, the gate cannot be moved until the operating mode changes to deadman operation (after 3 minutes).
C: BUS:
programme parameter "P07" = 4. Self-learning must be repeated after the cell BUS has been connected.
If cells are removed, it is essential to create the bridge between terminals 19 and 20.
It is compulsory to install photoelectric cells if:
- the automatic control device is being controlled remotely (user unable to see it),
- automatic closing is activated (P01 = 1, 3 or 4).
It is compulsory to install photoelectric cells WITH AUTOTEST (P07 = 3 or 4) if the automatic control device is being controlled by a Tahoma
control box.
5HÀH[SKRWRHOHFWULFFHOO)LJ
Without autotest:
programme parameter "P07" = 1.
With autotest:
programme parameter "P07" = 2.
Allows an automatic test to be carried out to check the operation of the photoelectric cell each time the gate moves.
If the operating test result is negative, the gate cannot be moved until the operating mode changes to deadman operation (after 3 minutes).
It is compulsory to install photoelectric cells WITH AUTOTEST (P07 = 2) if the automatic control device is being controlled by a Tahoma
control box.
Orange light (Fig. 3)
Programme parameter "P12" according to the required operating mode:
No warning prior to gate movement:
"P12" = 0.
With 2 s warning prior to gate movement:
"P12" = 1.
Connect the aerial cable to terminals 7 (conductor) and 8 (braid).
Wired code keypad (Fig. 4)
Not operational using solar power.
Aerial (Fig. 5)
Safety edge (Fig. 6)
Not operational using solar power.
Only active when closing (for a safety edge active when opening, use the programmable safety input and programme parameter "P10" = 1).
With autotest: programme parameter "P08" = 2.
Allows an automatic test to be carried out to check the operation of the safety edge each time the gate moves.
If the operating test result is negative, the gate cannot be moved until the operating mode changes to deadman operation (after 3 minutes).
If the safety edge is removed, it is essential to create the bridge between terminals 17 and 18.
24 V battery (Fig. 7)
[1].
Position and tighten the battery power supply management card.
[2].
Position the batteries.
[3].
Make the connections.
For more details, refer to the 24V battery instructions.
Normal operation: nominal speed, accessories functional.
Life: 5 cycles/24 hrs
9.6 V battery (Fig. 8)
Degraded operation: speed reduced and constant (no slowdown at end limit), 24 V accessories inactive (including cells).
Life: 5 cycles/24 hrs
Solar kit (Fig. 9)
$GMXVWWKHOHQJWKRIWKHFDEOHFRQQHFWLQJWKHPRWRUWRWKHEDWWHU\KRXVLQJ,WVKRXOGEHDVVKRUWDVSRVVLEOHWRSUHYHQWYROWDJHGURSV
5m cable provided with the solar kit.
Note:
Join wires of the same colour to prevent polarity reversal.
Area lighting (Fig. 10)
For class I lighting, connect the earth wire to the earth terminal on the base of the motor.
Note:
The earth wire must always be longer than the live and neutral wires in case of detachment.
Several lights may be connected provided the total power does not exceed 500 W.
CONNECTING ADDITIONAL DEVICES
Summary of Contents for Elixo 500 3S RTS
Page 1: ...D811950_03_15 01 2015 ELIXO 500 3S RTS EN Installation instructions TR 0RQWDM N ODYX X FA AR...
Page 2: ......
Page 64: ...FAElixo 500 3S RTS 2 Copyright 2015 Somfy SAS All rights reserved 1 www somfy com...
Page 84: ...ARElixo 500 3S RTS Copyright 2015 Somfy SAS All rights reserved 3 10 30 2 2400484 1 5 50...
Page 87: ......