EN
Dexxo Compact RTS
3
Copyright © 2015 Somfy SAS. All rights reserved
> Safety devices
WARNING
For operation in automatic mode or remote control,
photoelectric cells must be installed.
In automatic mode, the drive operates in at least one
direction with no intentional activation by the user.
For operation in automatic mode or if the garage door faces
a public road, installation of an orange light may be required
to comply with the regulations in the country in which the
drive is installed.
> Clothing precautions
Take off any jewellery (bracelet, chain, etc.) during
installation.
For manoeuvring, drilling and welding operations, wear
appropriate protection (special glasses, gloves, ear
protection, etc.).
1.6 Regulations
Somfy SAS declares that the product described in
these instructions, when used in accordance with these
instructions, complies with the essential requirements of the
applicable European Directives and, in particular, with the
Machinery Directive 2006/42/EC and the Radio Equipment
Directive 2014/53/EU.
The full text of the EC declaration of conformity is available
on the following website: www.somfy.com/ce. Antoine
CREZE, Head of Regulations, Cluses
1.7 Assistance
You may encounter difficulties or have questions when
installing your drive.
Do not hesitate to contact us; our specialists are on hand to
answer all your questions.
Internet: www.somfy.com
1.8 Risk prevention
WARNING
Risk prevention - motorisation of sectional/up and
over garage door for residential usage
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 4
Zone 1
Zone 2
Zone 3
Zone 5
Zone 4
Risk zones: measures to be taken to eliminate risks.
RISK
SOLUTION
ZONE 1
Risk of crushing
between the ground
and the lower edge
of the door during
closing
Obstacle detection built into the
drive.
Obstacle detection must be
confirmed as being compliant
with Appendix A of standard EN
12 453
For operation with automatic
closing, install photoelectric cells
ZONE 2
Risk of crushing
between the lintel and
the upper edge of the
door during closing
Obstacle detection built into the
drive.
Obstacle detection must be
confirmed as being compliant
with Appendix A of standard EN
12 453
ZONE 3
Risk of cutting or
trapping between the
door panels in gaps
of between 8mm and
25mm
Eliminate all sticking points and
all sharp edges from the surface
of the door
Eliminate any gap ≥ 8 mm or ≤
25 mm
ZONE 4
Risk of trapping
between the roller rails
and bearings
Eliminate all sharp edges on the
guide rails
Eliminate any gap ≥ 8 mm
between the rails and the
bearings
ZONE 5
Risk of crushing
between the secondary
edges and adjoining
fixed parts
Obstacle detection built into the
drive.
Obstacle detection must be
confirmed as being compliant
with Appendix A of standard EN
12 453
Summary of Contents for Dexxo Compact RTS
Page 1: ...EN Installation instructions Dexxo Compact RTS 5072364E ...
Page 9: ......