background image

EN

Dexxo Compact RTS

Copyright © 2015 Somfy SAS. All rights reserved

4 - PROGRAMMING

4.1  Description of the programming buttons

flashing

off

Indicator light key

Buttons

Function

 -Triggers auto-programming 

 -Memorising/clearing the remote controls

 -Modifying the value of a setting
 -Using forced operating mode

 -Selecting a setting

I n d i c a t o r 

light A

 -Parameter indicator light selected

I n d i c a t o r 

light B

 -Parameter value indicator light

 -Fault indicator light

4.2  Auto-programming - Fig. 15

[1]. 

 Control  the  motor  with  button  “A”  so  that  the  transmission  shuttle  is 

engaged on the carriage and bring the door to the closed position:

-  Keep button “A” depressed to cause the shuttle to move.

-  Release the button to stop the movement.

-  Keep button “A” depressed again to trigger movement in the opposite

direction.

Release button “A” before forcing the motor on the door.

[2]. 

  Adjust the closed position using button “A”. 

Release button “A” before forcing the motor on the door.

[3]. 

Press “B” to launch the auto-programming cycle.

The door performs a complete Opening-Closing cycle.

-  If the auto-programming is correct, indicator light B goes out.

-  If  the  auto-programming  cycle  was  not  successful,  indicator  light  B

continues to flash (2 flashes).

During auto-programming:

-  If the door is moving, the movement is stopped and auto-programming is

interrupted if any of the buttons is pressed.

It is possible to access auto-programming mode at any moment including when 

the auto-programming cycle has already been completed.

Note: The remote controls supplied in the kit have already been 

memorised.

 WARNING

At the end of installation, it is essential to check that the obstacle 

detection complies with appendix A of standard EN 12 453.

4.3  Locking access to the parameters (button A) - Fig. 

16

Press button A repeatedly until the indicator light A flashes 4 times.

Press button B once: 

- The parameters menu (button A) is locked.

 WARNING

Once installation is complete, the parameters menu must always be 

locked to ensure the safety of users. 

Failure to follow this instruction may result in serious injury, e.g. due to 

crushing by the gate.

At this stage of the installation, the Dexxo Compact RTS drive is 

ready to operate.

5 - OPERATING TEST

5.1 Using the remote controls - Fig. 17
5.2  Obstacle detection operation - Fig. 18 and 19

When an obstacle is detected during closing, the door re-opens 

(Fig. 18)

.

When  an  obstacle  is  detected  during  opening,  the  door  will  stop  

(Fig. 19)

.

Check that the obstacle detection function works when the door encounters a 

50 mm high obstacle on the ground.

5.3 Integrated lighting operation

The lighting comes on each time the drive is switched on. When the door stops 

moving, it goes off automatically after 30 seconds. Repetitive use will cause 

the light to be lit constantly which may result in the light being switched off 

automatically due to thermal protection.

5.4 User training

All users must be trained on how to safely use this door (standard use and 

locking principle) and on the mandatory periodic checks.

6 - CONNECTING ADDITIONAL DEVICES

6.1  Description of the different additional devices - 

Fig. 20

No.

Description

1

Orange light

2

Wired code keypad

3

Key lock

4

Aerial

5

Battery

6

Photoelectric cells

6.2  Electrical connection of the additional devices- 

Fig. 20 to 23

Switch off the electrical supply to the motor before performing any operation on 

the additional devices. 

General electrical diagram (Fig. 20)
Photoelectric cells (Fig. 21)

When positioning the cells, remove the bridge created between terminals 1 

and 2.

If cells are removed, it is essential to recreate the bridge between 

terminals 1 and 2.

Solar kit (Fig. 22)

Activate solar mode by adjusting the motor power supply type (see below).

Wired code keypad (Fig. 23)

Summary of Contents for Dexxo Compact RTS

Page 1: ...EN Installation instructions Dexxo Compact RTS 5072364E ...

Page 2: ...r 1 2 Introduction Important information This product is a drive for vertically or horizontally opening garage doors for residential use as defined in standard EN 60335 2 95 and EN 60335 2 103 with which it complies The mainpurposeoftheseinstructionsistosatisfytherequirements of the aforementioned standards and to ensure the safety of equipment and persons CONTENTS Translated version of the instal...

Page 3: ...ive and equipped with protection comprising a 10 A fuse or breaker a differential type device 30 mA An all pole power supply cut off device must be provided It is recommended that you fit a lightning conductor maximum residual voltage 2 kV Cable feed Underground cables must be equipped with a protective sheath with a sufficient diameter to contain the motor cable and the accessories cables For ove...

Page 4: ...sitate to contact us our specialists are on hand to answer all your questions Internet www somfy com 1 8 Risk prevention WARNING Risk prevention motorisation of sectional up and over garage door for residential usage Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 4 Zone 1 Zone 2 Zone 3 Zone 5 Zone 4 Risk zones measures to be taken to eliminate risks RISK SOLUTION ZONE 1 Risk of crushing between the groun...

Page 5: ... sections of the rail Ensure that the chain or belt is not twisted 4 Assemble the 2 sections of the rail using the sleeve 5 Secure the assembly using 8 mounting screws 6 Tighten the nut to tension the chain or belt The compressed rubber must measure 18 and 20 mm The mounting screws must not penetrate the rail do not drill In the case of an attached ceiling installation do not use the sleeve mounti...

Page 6: ...Fig 16 Press button A repeatedly until the indicator light A flashes 4 times Press button B once The parameters menu button A is locked WARNING Once installation is complete the parameters menu must always be locked to ensure the safety of users Failure to follow this instruction may result in serious injury e g due to crushing by the gate At this stage of the installation the Dexxo Compact RTS dr...

Page 7: ...plied in the kit have already been memorised It is possible to memorise up to 32 control channels If this procedure is carried out using a channel which has already been memorised this channel will be cleared Memorising a Telis type remote control or similar Fig 27 8 SPECIFIC OPERATION See the user booklet 9 CLEARING THE REMOTE CONTROLS AND ALL SETTINGS 9 1 Deleting remote controls Fig 28 Press bu...

Page 8: ...s 2 double insulated Integrated lighting 24 V 20 W G4 halogen bulb Radio frequency 433 42 MHz 10 mW Number of storable channels 32 CONNECTIONS Safety input Type Dry contact NF Compatibility TX RX photoelectric cells Wired control input Dry contact NO Orange light output Flashing output for orange light 24 V 15 W Accessories supply output 24 V 500 mA max Offset aerial input Yes compatible with RTS ...

Page 9: ......

Page 10: ...Somfy SAS capital 20 000 000 Euros RCS Annecy 303 970 230 01 2017 Somfy 50 avenue du Nouveau Monde BP 152 74307 Cluses Cedex France www somfy com ...

Reviews: