background image

EN

Dexxo Compact RTS

Copyright © 2015 Somfy SAS. All rights reserved 

2

 WARNING

Any  use  of  this  product  outside  the  field  of  application 

described in these instructions is prohibited (see "Field of 

application" paragraph in the installation manual). 

The use of any accessories or components not 

recommended by Somfy is prohibited, as personal safety 

cannot be guaranteed. 

Any failure to comply with the instructions given in this 

guide shall exclude Somfy from all liability and invalidate 

the Somfy warranty. 

In case of any doubts when installing the drive, or to obtain 

additional information, consult the website www.somfy.com.

The instructions may be modified if and when there is a 

change to the standards or to the drive.

1.3 Preliminary checks

 > Installation environment

ATTENTION

Do not spray water onto the drive.

Do not install the drive in an explosive environment.

 > Condition of the door to be motorised

Before installing the drive, check that:

 - the door is in good mechanical condition

 - the door is correctly balanced

 - The  structures  of  the  garage  (walls,  lintel,  partitions, 

ceiling,  etc.)  enable  the  drive  to  be  fixed  securely. 

Strengthen these if necessary.

 - the door can be correctly opened and closed manually 

using a force of less than 150 N.

 DANGER

CAUTION: It is dangerous to perform any operation on the 

door springs (the door may fall).

 >

Specifications of the door to be motorised

After installation, ensure that the parts of the door do not 

encroach onto the pavement or public thoroughfare.

 WARNING

If the garage door is fitted with a wicket door, the door 

must be equipped with a system that prevents it from 

moving when the wicket door is not in the safety position.

1.4 Electrical installation

 DANGER

The installation of the power supply must comply with 

the standards in force in the country in which the drive is 

installed, and must be carried out by qualified personnel.

The electric line must be exclusively reserved for the drive 

and equipped with protection, comprising: 

 -a 10 A fuse or breaker, 

 -a differential type device (30 mA).

An all-pole power supply cut-off device must be provided.

It  is  recommended  that  you  fit  a  lightning  conductor 

(maximum residual voltage 2 kV).

 > Cable feed

Underground cables must be equipped with a protective 

sheath with a sufficient diameter to contain the motor cable 

and the accessories cables.

For  overground  cables,  use  a  cable  grommet  that  will 

withstand the weight of vehicles (ref. 2400484).

1.5 Safety instructions relating to installation

 WARNING

Before installing the drive, remove any unnecessary cords 

or chains and deactivate any locking device (bolt) which is 

not required for motorised operation.

 DANGER

Do not connect the drive to a power supply (mains, battery 

or solar) until installation is complete.

 WARNING

Ensure that any danger zones (crushing, cutting, trapping) 

between  the  driven  part  and  the  surrounding  fixed 

elements caused by the opening movement of the driven 

part are avoided or indicated on the installation 

(see "Risk 

prevention")

.

Permanently affix the crushing warning labels near to any 

fixed control devices, and so that they are extremely visible 

to the user.

 WARNING

Modifying one of the elements provided in this kit or using 

an additional element not recommended in this manual is 

strictly prohibited.

Monitor the door as it moves and keep people away from it 

until installation is complete.

Do not use adhesive to secure the drive.

Install the internal manual back release device at a height 

of less than 1.8 m.

Permanently  affix  the  label  concerning  the  manual  back 

release device near to its mobile component.

 WARNING

Take care when using the manual back release device as 

an open door can suddenly fall off if the springs are weak, 

broken, or incorrectly balanced.

ATTENTION

Install  any  fixed  control  device  at  a  height  of  less  than 

1.5 m and within sight of the door, but away from moving 

parts.

After installation, ensure that:

 -the mechanism is correctly adjusted 

 - the manual back release device is operating correctly

 - the drive changes direction when the door encounters an 

object 50 mm high on the ground.

Summary of Contents for Dexxo Compact RTS

Page 1: ...EN Installation instructions Dexxo Compact RTS 5072364E ...

Page 2: ...r 1 2 Introduction Important information This product is a drive for vertically or horizontally opening garage doors for residential use as defined in standard EN 60335 2 95 and EN 60335 2 103 with which it complies The mainpurposeoftheseinstructionsistosatisfytherequirements of the aforementioned standards and to ensure the safety of equipment and persons CONTENTS Translated version of the instal...

Page 3: ...ive and equipped with protection comprising a 10 A fuse or breaker a differential type device 30 mA An all pole power supply cut off device must be provided It is recommended that you fit a lightning conductor maximum residual voltage 2 kV Cable feed Underground cables must be equipped with a protective sheath with a sufficient diameter to contain the motor cable and the accessories cables For ove...

Page 4: ...sitate to contact us our specialists are on hand to answer all your questions Internet www somfy com 1 8 Risk prevention WARNING Risk prevention motorisation of sectional up and over garage door for residential usage Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 4 Zone 1 Zone 2 Zone 3 Zone 5 Zone 4 Risk zones measures to be taken to eliminate risks RISK SOLUTION ZONE 1 Risk of crushing between the groun...

Page 5: ... sections of the rail Ensure that the chain or belt is not twisted 4 Assemble the 2 sections of the rail using the sleeve 5 Secure the assembly using 8 mounting screws 6 Tighten the nut to tension the chain or belt The compressed rubber must measure 18 and 20 mm The mounting screws must not penetrate the rail do not drill In the case of an attached ceiling installation do not use the sleeve mounti...

Page 6: ...Fig 16 Press button A repeatedly until the indicator light A flashes 4 times Press button B once The parameters menu button A is locked WARNING Once installation is complete the parameters menu must always be locked to ensure the safety of users Failure to follow this instruction may result in serious injury e g due to crushing by the gate At this stage of the installation the Dexxo Compact RTS dr...

Page 7: ...plied in the kit have already been memorised It is possible to memorise up to 32 control channels If this procedure is carried out using a channel which has already been memorised this channel will be cleared Memorising a Telis type remote control or similar Fig 27 8 SPECIFIC OPERATION See the user booklet 9 CLEARING THE REMOTE CONTROLS AND ALL SETTINGS 9 1 Deleting remote controls Fig 28 Press bu...

Page 8: ...s 2 double insulated Integrated lighting 24 V 20 W G4 halogen bulb Radio frequency 433 42 MHz 10 mW Number of storable channels 32 CONNECTIONS Safety input Type Dry contact NF Compatibility TX RX photoelectric cells Wired control input Dry contact NO Orange light output Flashing output for orange light 24 V 15 W Accessories supply output 24 V 500 mA max Offset aerial input Yes compatible with RTS ...

Page 9: ......

Page 10: ...Somfy SAS capital 20 000 000 Euros RCS Annecy 303 970 230 01 2017 Somfy 50 avenue du Nouveau Monde BP 152 74307 Cluses Cedex France www somfy com ...