![background image](http://html.mh-extra.com/html/somfy/dexxo-compact-rts/dexxo-compact-rts_installation-instructions-manual_1317606008.webp)
EN
Dexxo Compact RTS
7
Copyright © 2015 Somfy SAS. All rights reserved
12 - DIAGNOSTICS
Indicator light B
Meaning
Solution?
2
Motor waiting for auto-
programming
Start auto-programming
3
Cell fault
Check that no obstacles
prevent the cells from
detecting.
Check the wiring of the cells
or create a bridge between
terminals 1 and 2 if no cells
are installed.
Check the correct alignment of
the cells.
5
Motor thermal
protection device
Leave the motor to cool until
the fault disappears.
6
Motor current
measuring circuit fault
or sensor fault
Switch off the power supply
(mains and backup battery),
wait a few minutes then
reconnect the power supply.
Perform an auto-programming
cycle. If the fault persists,
contact Somfy technical
support.
7
Maximum power
delivered by the motor
reached during the
auto-programming
phase
Product has reached
operating limit.
13 - TECHNICAL DATA
GENERAL SPECIFICATIONS
Power supply
230 V - 50 Hz
Max. power
consumption
Standby
4 W
Operation
120 W
Max. tensile force
600 N
Use
semi-intensive
Maximum speed
14 cm/s
Programming interface
2 buttons - 2 indicator lights
Climatic operating conditions
- 20°C / + 60°C - dry interior IP 20
End limits
Mechanical stop when opening
Electronic when closing: stored
closing position
Electrical insulation
Class 2: double-insulated
Integrated lighting
24 V 20 W G4 halogen bulb
Radio frequency
433.42 MHz
< 10 mW
Number of storable channels
32
CONNECTIONS
Safety input
Type
Dry contact: NF
Compatibility
TX/RX photoelectric cells
Wired control input
Dry contact: NO
Orange light output
Flashing output for orange light: 24
V - 15 W
Accessories supply output
24 V - 500 mA max
Offset aerial input
Yes: compatible with RTS aerial
(part no. 2400472)
Backup battery
input
Yes: compatible with battery pack
(part no.: 9001001)
Battery life
24 hours; 5 to 10 cycles depending
on the door
Recharging time 72 hours
OPERATION
Forced operating mode
By pressing and holding button “A”
Timed lighting (after movement)
Fixed: 30 s
Orange light warning
2 sec. automatic if light connected
Security entry
operation
When closing
Total reopening
Before opening
(ADMAP)
With
Integrated obstacle detection
Adjustable sensitivity: 4 levels
Operation in the event of obstacle
detection
Total reopening
Gradual starting
Yes
Opening speed
Fixed: 14 cm/s (max.)
Closing speed
Fixed: 12 cm/s (max.)
Docking speed when closing
Programmable: no reduction in speed,
short slow zone (30 cm), long slow zone
(50 cm)
13.1 Dimensions
Longueur hors tout : 3154,6
171 mini
140
63,7
125
147,
1
152,
7
Longueur hors tout : 3127,6
Course utile : 2555
Fixation : 2981,7
Rail : 2900
Rail : 2900
65
33,
5
11
9,
6
11
4
173
173
86,5
173
113,5
11
3,
5
269,7
269,
7
Overall length: 3154.6
Overall length: 3127,6
Working stroke: 2555
Rail: 2900
Rail: 2900
Mounting: 2981,7