Dexxo Compact RTS

Copyright © 2015 Somfy SAS. All rights reserved 

6

7 - PARAMETER SETTING AND 

OPERATING OPTIONS

7.1 General parameter setting diagram - Fig.24
7.2 Meaning of different parameters

Programming example: Adjusting the long slow zone (Fig. 25)

Indicator 

light A 

Obstacle detection sensitivity

Indicator 

light B

1 : very low sensitivity
2

: slightly sensitive

 : standard

4

: very sensitive

 WARNING

If this parameter is changed, the installer must check that the obstacle 

detection complies with appendix A of standard EN 12 453.

Failure to follow this instruction may result in serious injury, e.g. due to 

crushing by the gate.

Indicator 

light A 

Docking speed when closing

Indicator 

light B

1 : no reduction in speed

 : short slowing

3

: long reduction in speed

Comments

1: no reduction in speed at the end of closing.

2: the speed is reduced during the last 20 centimetres.

3: the speed is reduced during the last 50 centimetres.

 WARNING

If this parameter is changed, the installer must check that the obstacle 

detection complies with appendix A of standard EN 12 453.

Failure to follow this instruction may result in serious injury, e.g. due to 

crushing by the gate.

Indicator 

light A 

Auto-programming mode

Indicator 

light B

2

: waiting for auto-programming

0    : self-learning is complete

Indicator 

light A 

Locking the parameters menu

Indicator 

light B

0    : 

the parameters menu is locked

If button B is pressed accidentally, move on to step 10 to unlock the 

parameters menu

Indicator 

light A 

Power supply

Indicator 

light B

1   : power supply

 : solar

Memorising the remote control for operation in “Partial opening” 

mode (Fig. 26)

The remote controls supplied in the kit have already been memorised.

It is possible to memorise up to 32 control channels.

If this procedure is carried out using a channel which has already been 

memorised, this channel will be cleared.

Memorising a Telis type remote control or similar (Fig. 27)

8 - SPECIFIC OPERATION

See the user booklet.

9 - CLEARING THE REMOTE CONTROLS 

AND ALL SETTINGS

9.1  Deleting remote controls - Fig. 28

Press button “

B

” until the light flashes (7 sec.).

Causes all memorised remote controls to be cleared.

9.2  Reinitialising all settings - Fig. 29

[1]. 

 Press button “

A

” 3 times to access the auto-programming parameter.

[2]. 

 Press  button  "

B

” to enter auto-programming mode. Indicator light B 

flashes twice continuously. 

[3]. 

 Control  the  motor  with  button  “

A

” so that the transmission shuttle is 

engaged on the carriage and brings the door to the closed position.

[4]. 

Press “

B

” to launch the auto-programming cycle.

The door performs a complete Opening-Closing cycle.

 -If the auto-programming is correct, indicator light B goes out.

 - If  the  auto-programming  cycle  was  not  successful,  indicator  light  B 

flashes twice continuously.

10 - UNLOCKING THE PARAMETERS MENU 

FIG. 30

Note: If the parameters menu is locked and no memorised remote control 

is available, it will be necessary to memorise a remote control first (fig. 

26 or fig. 27).

[1]. 

Press and hold button A on the DEXXO COMPACT.

[2]. 

Without releasing button A, press a button on a remote control which is 

already memorised. The light on the DEXXO COMPACT comes on briefly 

to indicate that unlocking has taken place. 

[3]. 

Release button A.

 WARNING

Once the work being carried out by the professional is complete, the 

parameters menu must always be locked to ensure the safety of users. 

Failure to follow this instruction may result in serious injury, e.g. due to 

crushing by the gate.

11 - REFITTING THE COVER FLAP - FIG. 31

Fit the cover flap.

Summary of Contents for Dexxo Compact RTS

Page 1: ...EN Installation instructions Dexxo Compact RTS 5072364E ...

Page 2: ...r 1 2 Introduction Important information This product is a drive for vertically or horizontally opening garage doors for residential use as defined in standard EN 60335 2 95 and EN 60335 2 103 with which it complies The mainpurposeoftheseinstructionsistosatisfytherequirements of the aforementioned standards and to ensure the safety of equipment and persons CONTENTS Translated version of the instal...

Page 3: ...ive and equipped with protection comprising a 10 A fuse or breaker a differential type device 30 mA An all pole power supply cut off device must be provided It is recommended that you fit a lightning conductor maximum residual voltage 2 kV Cable feed Underground cables must be equipped with a protective sheath with a sufficient diameter to contain the motor cable and the accessories cables For ove...

Page 4: ...sitate to contact us our specialists are on hand to answer all your questions Internet www somfy com 1 8 Risk prevention WARNING Risk prevention motorisation of sectional up and over garage door for residential usage Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 4 Zone 1 Zone 2 Zone 3 Zone 5 Zone 4 Risk zones measures to be taken to eliminate risks RISK SOLUTION ZONE 1 Risk of crushing between the groun...

Page 5: ... sections of the rail Ensure that the chain or belt is not twisted 4 Assemble the 2 sections of the rail using the sleeve 5 Secure the assembly using 8 mounting screws 6 Tighten the nut to tension the chain or belt The compressed rubber must measure 18 and 20 mm The mounting screws must not penetrate the rail do not drill In the case of an attached ceiling installation do not use the sleeve mounti...

Page 6: ...Fig 16 Press button A repeatedly until the indicator light A flashes 4 times Press button B once The parameters menu button A is locked WARNING Once installation is complete the parameters menu must always be locked to ensure the safety of users Failure to follow this instruction may result in serious injury e g due to crushing by the gate At this stage of the installation the Dexxo Compact RTS dr...

Page 7: ...plied in the kit have already been memorised It is possible to memorise up to 32 control channels If this procedure is carried out using a channel which has already been memorised this channel will be cleared Memorising a Telis type remote control or similar Fig 27 8 SPECIFIC OPERATION See the user booklet 9 CLEARING THE REMOTE CONTROLS AND ALL SETTINGS 9 1 Deleting remote controls Fig 28 Press bu...

Page 8: ...s 2 double insulated Integrated lighting 24 V 20 W G4 halogen bulb Radio frequency 433 42 MHz 10 mW Number of storable channels 32 CONNECTIONS Safety input Type Dry contact NF Compatibility TX RX photoelectric cells Wired control input Dry contact NO Orange light output Flashing output for orange light 24 V 15 W Accessories supply output 24 V 500 mA max Offset aerial input Yes compatible with RTS ...

Page 9: ......

Page 10: ...Somfy SAS capital 20 000 000 Euros RCS Annecy 303 970 230 01 2017 Somfy 50 avenue du Nouveau Monde BP 152 74307 Cluses Cedex France www somfy com ...

Reviews: