Installation
19
EN
- EXAVIA installation and operating guide - SOMFY
EN
1
1.6 Connecting the motors
Motor M1 activates the gate leaf which:
•
opens first and closes last,
•
opens for pedestrian access.
1
M1 est à gauche
OU
M1 est à droite
M1 on the le
M1 on the right
With the gate closed, identify the gate
leaf that opens first.
Motor M1 activates this gate leaf.
2
Connect the motors as indicated in the table below:
Connect motor wire...
to terminal ...
M1
blue
10
brown
11
M2
blue
12
brown
13
M1
M1
M2
M2
11
11
13
13
10
10
12
12
BATT
BATT
+
+
-
-
FLASH
8
8
9
9
24V
+
1.7 Connecting to the mains power supply
For your safety, these operations must be carried out with the power supply switched off.
Use a 3 1.5 x 1.5 mm² cable for outdoor use (at least H07RN-F type).
The cable clamp supplied must be used. For all low-voltage cables, ensure that they can withstand traction of 100 N.
Check that the conductors have not moved when this traction has been applied.
1
2
4 cm
Live
Neutral
230 V power supply cable
NT
NT
BUS
BUS
3
3
2
2
4
4
5
5
6
6
START
ART
M1
M1
M2
M2
11
11
13
13
10
10
12
12
BATT
BATT
+
+
-
-
LIGHT
LIGHT
230V
230V
15
15
17
17
14
14
16
16
7
7
-
FLASH
8
8
9
9
24V
+
L
L
N
N
Neutral
Live
230 V power supply cable
Cable clamp
On a 3 x 1.5 mm² type cable, prepare 2 x 4 cm wires (live and
neutral).
•
Connect phase and neutral to terminals 16 and 17 (red "230 V"
label)
•
Immobilise the 230 V power cable with the cable-clamp
provided (r).
•
Fit a terminal block on the earth wire (yellow/green) and store
it in the control unit.