20
EN
- EXAVIA installation and operating guide - SOMFY
EN
COMMISSIONING AND STANDARD USE
2.1 Switching the installation on
The indicator light flashes (twice).
The motor is switched on and awaiting auto-programming.
If the indicator light does not come on or the number of flashes is not as expected: see “Diagnostics”, page 32.
2.2 Adjusting the opening stop
Opening end stop
The opening stops are integrated into the cylinder. They delimit the travel of the gate leaf when opening.
Your installation must be equipped with closing stops secured to the ground to mark out the travel of the gate when closing.
During this phase, pressing button 1 on the programmed remote control will only open and stop the gate
(1st activation = open, 2nd activation = stop, 3rd activation = open, 4th activation = stop, etc.). The desired opening position can thus be
adjusted several times. it will be possible to close the gate once the opening stops are installed.
1
STOP
•
Press button 1 on the remote control.
Aer a few seconds, the first gate leaf
opens, slowly.
If the gate leaf does not open, check that
the motors are wired as shown page 19.
•
Press button 1 on the remote control again
to stop the gate leaf in the desired opening
position.
2
If required, to fine-tune the opening position
of the gate, open the flap at the end of the
cylinder then screw it in or unscrew it to
obtain the desired opening angle.
3
1
2
Do not remove the screws from the stop.
Position the opening stop (
1
) in contact with
the cylinder knob (
2
) then tighten the stop
using a 10 mm offset wrench.
5
Press button 1 on the remote control.
The second gate leaf opens.
2