ADVANCED PARAMETER SETTINGS
4.1 Pedestrian opening
Pedestrian opening operation
Pedestrian opening
(motor M1) by pressing the activated button.
Stop
when moving by pressing the activated button again.
STOP
Close
by pressing the activated button again.
Activating the pedestrian opening
Button 1 on 2- or 4-button remote controls cannot be programmed to control pedestrian opening.
See “Programming the remote controls”, page 28 for more information.
1
2
3
>2s
<0,5s
Press the
button on the control
electronics for 2 seconds.
The indicator light comes on.
Position the remote control on the control
electronics target.
Press button 2 on the remote control.
The “RADIO” and
indicator lights come
on then go out.
Pedestrian opening is activated on this
button.
Move away from the control electronics when testing pedestrian opening.
Deactivating the pedestrian opening
Repeat the “Activate pedestrian opening” procedure using the button for which the pedestrian opening must be deactivated. The indicator light
comes on then goes out. The pedestrian opening is deactivated on this button.