12
EN
- EXAVIA installation and operating guide - SOMFY
EN
INSTALLATION
1.1 Measuring the dimensions
Take the dimensions using disc (f) to determine the position of the motors on the pillars.
Note:
For these measurements, the gate leaves and their hinge pins are assumed to be on the same axis.
N.B.:
You must leave a minimum distance of 50 cm between the gate leaves and the fixed sections (see “Risk prevention”, page 4).
Recommended: dimension A is negative
If dimension A is negative, the gate leaf hinge is located in front of the pillar.
We recommend that you add a shim so that the cylinder mounting bracket is
aligned with the gate leaf hinge and A is 0 cm.
= 0 cm
< 0 cm
1
Take care to ensure the bracket is
fitted the right way up.
Measure dimension A.
Transfer the measured
dimension A on the disc.
The maximum opening
angle α is stated.
Determine dimension B
ATTENTION
Dimensions not recommended
for gate leaves > 2 metres
Angle
up to
Bracket direction of fitting "e" or "E"
Le-hand pillar
Right-hand pillar
Direction “E”
Direction “e”
1
3
2
4
The direction of fitting (e or E) of the cylinder mounting
bracket is stated.
Correct
orientation
Incorrect
orientation
Observe the maximum opening
angle given by the disc.