Troubleshooting guide
31
EN
- EXAVIA installation and operating guide - SOMFY
EN
6
6.3 Clearing the settings
When should I clear the settings?
•
Aer programming the gate leaf travel, if you change the opening position stop or if you modify the motor wiring.
•
If the gate opens at random due to normal wear of the gate.
1
2
3
4
>2s
Press the
button on the
control electronics for 2
seconds.
The indicator light
comes on.
Place the memorised remote
control on the target.
Keep button 1 of the remote
control depressed until the
indicator light
flashes.
Press button 1 on the remote
control once.
The "RESET" indicator light
flashes.
5
To delete the settings*
5
To delete the settings* and the remote controls/
memorised control points
Keep button 2 of the remote control depressed
until the
RESET indicator light comes on
.
Keep button 2 of the remote control depressed
until all the
indicator lights come on.
6
Indicator light flashes twice (see “Gate travel auto-
programming”, page 21).
*Gate travel, deactivation of parameter, etc.
6.4 Unlocking/locking the motors
When unlocking the motors, the gate may be manoeuvred manually if there is an electrical fault.
1
2
3
Open the flap at the end of the cylinder,
then gently unscrew to relieve the
pressure on the gate.
Unlocking the motors
Unclip that unlocking mechanism,
then remove the cylinder from the leaf
mounting bracket.
Locking the motors
Fit the cylinder. Clip the unlocking
mechanism on the catch to secure it.