38
a)
b)
c)
Figure 19
– Remote command unit (chrono-thermostat) and connection interface – both not
included.
This board has two entries "remote" and "therm" to conect the chrono-thermostat into
the "remote" the user of the start (closed contact NC) and stop (open contact NO) the
boiler.
If connecting into the "thermostat" This will only change the power of the machine
between minimum output (open contact NO) and maximum power (closed contact NC).
Note: the external command, as a rule, comes with a manual. In the case of wireless
remote control is necessary to connect the two wires as shown in the following figure: