Selecting the operating mode
:
To select the operating mode, press the “Mode” key
to select “Manu” for manual mode or “Auto” for automatic mode.
ON
OFF
OF
F
+
OK
OFF
MENU
OFF
MODE
OFF
ESC
OFF
-
MAN
AUT
OFF
Mode:AUTO
Menu
Temp:30ºC
Fan:5
Auto mode
:
In this mode, the unit is turned on at maximum power until reaching a
temperature 1ºC above the selected temperature (set point temperature). After
reaching the selected temperature, the unit switches to the minimum operating power.
The set-point temperature can be set between 5 and 40ºC by pressing the "-" key.
The "+" key allows the user to set the fan speed between 1-5 or to automatic
operation.
“Manu” mode”: In this mode, the unit will operate at the speed selected using the "-"
key, ranging between 1 (minimum operating power) and 5 (maximum operating
power)
9.2.2.
Water temperature
Press the Menu key twice to set the water temperature;
"Temp. Agua" (Water Temp.) appears on the display. Press Set to see the "T.
Aquecimento" (Heating T.) menu.
ON
OFF
OF
F
+
OK
OFF
MENU
OFF
MODE
OFF
ESC
OFF
-
MAN
AUT
OFF
esc
Set
<
Temp. Água
>
Heating temperature
To set the desired heating temperature press “set”; the display starts to flash. Press
the “+” or “-“ key to select the desired value and then “ok” to confirm. Press the "+"
key to go to the "Temperatura de sanitários" (Bathroom Temperature) menu.
Summary of Contents for Douro 12kW
Page 13: ...12 a b ...
Page 50: ...49 ...
Page 51: ...50 ...
Page 52: ...51 ...
Page 58: ...57 18 Electrical Diagram of the Free Standing Fire Unit Figure 40 Electrical diagram ...
Page 70: ...69 21 Annexes 21 1 Flow chart Lighting ...
Page 71: ...70 ...
Page 72: ...71 Disabling ...