Alarm / Failure / Recommendation List
Table 2 - List of alarms
Important notice: when triggered, all the alarms above cause the machine to
shutdown. The alarm must be reset and the unit restarted. To reset the unit, press
the “On/Off” button for 10 seconds until the alarm sounds.
Alarm
Code
Cause and Troubleshooting
Ignition failure
A01
Maximum time 900s
- The worm drive channel is empty - restart the unit
- Resistance burnt – replace the resistance
- The burning basket has been incorrectly installed
- Locked worm - unlock
- Smoke temperature ñ exceeded the value defined in
the captivation
No
flame
or
insufficient
quantity of pellets
A02
Temperature under:
- 40 °
- Pellet reservoir is empty
Pellet drum temperature is
too high
A03
110 °C
- The fan is not working – call for assistance
- Faulty thermostat - call for assistance
- Faulty ventilation of the unit
Fume temperature is too high
A04
Over 260 °C
- The fan is not working or is working at a low speed -
increase level to the maximum (if the problem persists,
call for assistance)
- Insufficient extraction
- Excess pellets - Faulty smoke sensor
Pressure regulator alarm
A05
Door open, draught too low
or extractor fault for 60 sec
- Close the door and clear the error message on the
faulty pressure switch
- Obstruction of the exhaust pipe or faulty extractor
Air mass probe
A06
40 Ipm delta for 3600 sec
- Piping with insufficient draft or obstructed tubing
The door is open
A07
Door open for 60 seconds
- Close the door - clear the error message
Fume extractor is faulty
A08
Connection failure
- Faulty air mass sensor
Fume probe failure
A09
Connection failure
- Check connection
Pellet resistance error
A10
Connection failure
- Check that the fan is not blocked
Worm drive error
A11
Connection failure
- Check connection
Pellet level alarm
A15
- Check connection
Water pressure outside
operating range
A16
- Faulty resistance
Excess water temperature
A18
- Check connection
Summary of Contents for Atlantic
Page 77: ...76 ...
Page 78: ...77 ...
Page 79: ...78 ...
Page 85: ...84 20 Electrical Diagram of the Fire Unit Figure 68 Electrical diagram ...
Page 100: ...99 25 2 Flow chart Flow chart 1 Lighting ...
Page 101: ...100 ...
Page 102: ...101 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...