background image

Set the incoming stream as 

“Pull(BRTP)” 

since the IP

address of coder is unknown. In the field URL enter the
IP of the transmitter plant (decoder) and the same port
number assigned to decoder. 

In a full-duplex link, both units must work with the same
audio format.  

MPEG are NOT SUPPORTED for full-

duplex mode.

ADA102 at the Transmitter Plant

At   the   Transmitter   Plant   ADA102   receives   the

streaming

 from Studios. 

Set  

“Outgoing stream”

   as  

“Pull(BRTP)”

  since is the

coder   from   studios   who   starts   the   connection.   IP
address is zero and the Port number mus be the used
in the section “Incoming stream” in Studios. 

Set 

“Incoming stream”

 as 

“Push(RTP)”

 with IP address

zero,   since   the   coder   starts   the   connection   to   the
decoder. 

2.3.3 Link with repeaters

In   this   mode   the   coder   send   streaming   to   several
devices simultaneously. This configuration is common
when you have a static IP to the 

“multicast”

 group and

requires a half-duplex link. In both Studio ans in Plant,
ADA102 is set as “Multicast”  

(Configuration → Basic

settings → Stream Method).

Multicast   is   a   protocol   designed   for   maximum
efficiency   of   the   networks   when   required
simultaneous transmission from one point to multiple
destinations. Both  the  transmitter and receiver use
the same IP address, which should be in a special
range   of   IP   addresses   for   a   multicast. This   range
includes   addresses   from   224.0.0.0   to
239.255.255.255. 

To   implement   this   scheme,   see   your   network
administrator,   because   you   need   to   configure   the
multicast routers. 

ADA102 at the Studios

In this case ADA102 coder transmit to a multicast IP
address.   Coder   works   in   mode   “Multicast”

(Configuration → Stream Method)

.

 

ADA102 at the Transmitter Plant

The decoder also works as “Multicast”. In the field URL
you must define the same multicast IP used in the coder.

SOLIDYNE

ADA102 CODER/DECODER

Page 17

Summary of Contents for ADA102

Page 1: ......

Page 2: ......

Page 3: ...es at the studios with analogical connections 8 1 4 2 2 Full digital connections 9 1 4 2 3 Audio processor locates at transmission plant 9 1 4 3 Using an RF digital link 9 Section 2 software settings...

Page 4: ...a broadcasting FM transmitter The unit has four relay remotely managed At the encoder four inputs manages four switches on the decoder and vice versa The USB port lets you connect a pendrive when the...

Page 5: ...connectors used as is standard are female XLR 3 for the inputs and male for the outputs Take specially care with the phase Use one pair shielded audio cables of good quality preferably with double shi...

Page 6: ...and four outputs for remote control Each input can controls a switch off the remote unit Inputs are type dry inputs To enable an input input on send it to a GND pin of DB 15 The output switches 1 and...

Page 7: ...es If an error is detected the red led remains on and the device resets itself after the green LED has indicated the error as follows ERROR Green LED blinks Corrupt application or IP address conflict...

Page 8: ...the audio levels 1 4 2 1 Audio processor locates at the studios with analogical connections When the audio processor is at the Studio connected by analog input case a mentioned above the input level o...

Page 9: ...perate with digital signal To adjust the modulation depth proceed like the previous case MPX preset 1 4 2 3 Audio processor locates at transmission plant When ADA102 links the Studios to Transmission...

Page 10: ...SOLIDYNE ADA102 CODER DECODER Page 10...

Page 11: ...a password etc RESET the unit and return to step 3 8 Open up a new tab and type in MY IP and press enter Write this IP address down and send to the remote location technician This is the static IP yo...

Page 12: ...RANSMITTER DECODER 11 Click APPLY 12 Click CONFIGURATION tab Under Basic Setting stream method select PULL BRTP 13 For the URL you now need the STATIC IP address of the PUSH unit As discussed above to...

Page 13: ...he ADA102 listen to the IP address 192 168 0 6 using the Telnet command To do so type into the command window telnet 192 168 0 6 1 and hit the Enter key the number one must be there for this command t...

Page 14: ...er Level with Inactivity Timeout delay PULSE ON with IN audio change Relay will be pulse ON if audio input changes its state via Input Trigger Level with Inactivity Timeout delay ON while incoming str...

Page 15: ...ate Kbit s Audio Data Rate Kbit s Overhead sec Kbit s 1Kbit 1000 bits Audio Format Audio Data Rate Kbit s Packet sec Wireshark Overhea d bit Total Bit Rate Kbit s MPEG1 48KHz quality 0 stereo 88 41 7...

Page 16: ...ant will start the connection to the studios ADA102 at the Studios In the coder go to Configuration Basic settings and set the streaming method as Pull BRTP the URL as 0 0 0 0 and enter the listening...

Page 17: ...neously This configuration is common when you have a static IP to the multicast group and requires a half duplex link In both Studio ans in Plant ADA102 is set as Multicast Configuration Basic setting...

Page 18: ...SOLIDYNE ADA102 CODER DECODER Page 18...

Page 19: ...el with a peak hold system Channel Separation Better than 70 dB 1 kHz Analog Better than 90 dB 1 kHz Digital AES 3 Power supply 220 240V 110 127 V 50 60 Hz 15 VA Digital Streaming Input Output Streami...

Page 20: ...e a pre recorded radio program The user must record it on a Pen Drive using MP3 format The Emergency Radio Program could be only music or a complete program several hours long MPX output modelo ADA102...

Reviews: