EN.21
NOTE:
It is necessary to have two free sockets for connection of the BLINDS (see Figure
showing connection of the product):
-
socket for power supply to the product;
-
socket for power output to the grid.
Connect the BLINDS to the grid using a socket with grounding contact;
if necessary, use an extension cable or perform wiring works to install an equivalent
individual socket according to the current standards. Provide power supply from the
grid through a power cable with cross-section that corresponds to the current strength
at maximum capacity of the BLINDS (consumed and generated), but at least 0.5 mm
2
,
and having an separate insulated grounding wire;
ensure resistance of not more than 0.1 Ohm between the grounding element and
any other metal part of the BLINDS, which may potentially be touched
-
and where
dangerous voltages can be present.
NOTE
:
Use the BLINDS with the installed inverter only.
CAUTION!
The BLINDS contain components supplied by electrical power
(~230 V 50 Hz
and ~110 V 60 Hz
depending on the current standards). Therefore, wiring and grid
connection shall be performed by an authorised electrical technician having an
appropriate license (permit).
The BLINDS generate electric current when rolled down, therefore
wiring works
should be
performed with the
BLINDS rolled up and disconnected from the grid
.
Connectors on the DC output terminal of the inverter and battery, depending on
the package, may be without a plastic casing, only with metal contacts. In this case, in
any case,
do not allow metal contacts to touch each other
.