Can bus Warnings and Errors
CAN BUS
Indication LED
LED Status
Description
1
Green LED - Off
CANBUS interface disabled
Orange LED - Off
2
Green LED - Off
Line Open
No other devices detected on the Bus
Orange LED - Flashing with 1 short pulse
and 1 long pulse
3
Green LED - Solid on
Initialising
BMS in auto-configuration stage
Orange LED - Flashing fast
4
Green LED - Solid on
Duplicated BMS serial number
Possible causes non genuine BMS
connected
Orange LED - Flashing with 3 short
pulses and 1 long pulse
5
Green LED - Flashing fast
Communicating
Orange LED - Off
25