Troubleshooting Warnings / Errors
Code
Cause
Solution
1-2
1.
Inverter / rectifier settings may not be correct.
2.
Battery cells may be disbalanced
1.
Check the battery settings
2.
Contact Solar MD support
3-4
System design is not correct.
Add additional battery, decrease
charging / discharging current from
your inverter / rectifier / load
5-6
Manual override
Manual override has been activated -
please check with your installer
29-30
The BMS is ready to switch on after deep discharge / charge Connect charger / load to the Battery
5,6,7
The battery is not installed in upright position
Install the battery in the right position
15,16,17
The BMS has been shut down manually or remotely
Switch on the BMS
18,19
The absolute maximum charge/discharge current
has been achieved
The BMS will restart automatically,
please contact support team or
approved installer
21
The BMS is set for different number cells in series as the
actually installed
Contact your installer or Solar MD support
team
22
Battery cell voltage is way too low.
Fill in the failure report and
send to
The unit needs to return to the factory for
testing
23
Battery cell voltage way too high
The BMS will restart automatically after
pending awake condition
24,25,26,
27,28,30,
31
BMS Internal failure
Fill in the failure report and
send to
The BMS will be dispatched to
you for replacement
29
Battery factory failure
Fill in the failure report and
send to
The unit needs to return to the factory for
testing
CANBUS Warnings (page 29)
1
1.
Canbus line open.
2.
Single CANBUS resistor not terminated.
1.
Check if the minimum of
two nodes are connected on the line
with the same transmission speed.
2.
Check if single resistor is
terminated via the jumper. Located top
left of can LEDS(Fig 10).
27
Summary of Contents for SS4143-11
Page 1: ...INSTALLATION MANUAL SS4143 11 Advanced Lithium Ion battery 0 ...
Page 6: ...Mechanical installation 5 ...
Page 8: ...Figure 3b Battery spacing installation single or multiple batteries in line 7 ...
Page 9: ...Figure 3c Battery feet installation of battery feet 8 ...
Page 38: ...Annex A BMS EX Inverter Charger control and Cluster operation 37 ...
Page 44: ...3 1 3 3 Multiple inverters multiple batteries 43 ...