background image

S P E C I F I C AT I O N  

T a b l e   1 .   C a n a d a   a n d   U S A   H e a t e r s

 

 

 

Keep combustible material such as furniture, papers, clothes and 

 curtains at least  6 feet (1.8m) from the front of the heater and away 
 from the sides and rear.

 

W A R N I N G :   R I S K   O F   F I R E

W A R N I N G :   R I S K   O F   F I R E

W A R N I N G :   R I S K   O F   F I R E

W A R N I N G :   R I S K   O F   F I R E  

I N S TA L L AT I O N  

 

The 120V version of the heater is fitted with a supply cord measuring 15 feet (500 cm) and 
has a molded 3 - pin 15 amp plug. 
The  208  /  240V  version  of  the  heater  is  fitted  with  a  supply  cord  measuring  79  inches       
(200 cm) for hard wiring. 

 

WARNING: 

Wiring  procedures  and  connections  should  be  in  accordance  with  the         

National Electric Code (NEC) and local codes. 

 

WARNING: 

If the supply cord becomes damaged, it must be immediately replaced by a 

qualified person in order to avoid a hazard. 

 

CAUTION: 

Disconnect  electric  power  supply  before  working  on  circuit  wiring  to  prevent 

electric shock. 

 

CAUTION: 

Please observe the minimum safe distance between the heater body and any          

inflammable surfaces. 

 

CAUTION: 

When the electrical connection is outside a weatherproof socket must be used 

having ground fault protection (GFCI or GFI).

 

 Model Type 

SCOSYXL 

AW15120 

  SCOSYXL 

AW15240 

  SCOSYXL 

AW20240 

 Voltage 

120 V 

208 / 240 V 

 Total Power 

1500 W 

1125 / 1500 W 

1500 / 2000 W 

 Current 

12.5 A 

5.4 / 6.3 A 

7.2 / 8.3 A 

 Min. mounting height from floor 

79 in  (200 cm)

 

79 in  (200 cm) / 
103 in  (249 cm) 

 Min. distance from ceiling 

11¾ in  (30 cm)  

 

 Min. distance from side wall 

39½ in  (100 cm)   

 Dimensions - W × H × D 

 Weight 

6.2 lbs  (2.8 kg)   

22 in × 4½ in × 6¼ in  (56 cm × 11 cm × 16 cm) 

NOTE: CONSULT A QUALIFIED ELECTRICIAN, IF IN DOUBT.

 

!

 

WARNING  -  RISK  OF  FIRE:

 The 240 volt 2 kilowatt heater is not intended for use indoor 

residential or household heater but maybe used for commercial/industrial use. 

Summary of Contents for SCOSYXLAW15120

Page 1: ...WEATHERPROOF INFRARED HEATERS SUITABLE FOR OUTDOOR AND INDOOR USE RESIDENTIAL COMMERCIAL AND INDUSTRIAL INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga Ontario L4Z 2H3 Tel 905...

Page 2: ...n not in use or if hard wired disconnect the supply 6 Do not operate any heater with a damaged cord or plug or after the heater malfunctions has been dropped or damaged in any manner Return heater to...

Page 3: ...the use of an extension cord because the extension cord may overheat and cause a risk of fire 15 Do not cover or otherwise obstruct the heater 16 Do not touch the heater during operation as the body b...

Page 4: ...liance must be grounded 5 WARNING Keep the mains cord away from the body of the heater which will get hot during use 6 If a socket outlet is used do not position the outlet immediately behind the heat...

Page 5: ...on in order to avoid a hazard CAUTION Disconnect electric power supply before working on circuit wiring to prevent electric shock CAUTION Please observe the minimum safe distance between the heater bo...

Page 6: ...hen mounting or adjusting the heater position CAUTION When mounting the heater horizontally do not position the heater at an angle more than 50 or less then 45 as shown in Fig A CAUTION The heater sho...

Page 7: ...contact your local distributor quoting model type and rating from rating label It is very important that your replacement emitter is exactly the same as the one it was supplied with Failure to fit the...

Page 8: ...lace the emitter Contact your distributor for the correct replacement quoting model type and rating from rating label We recommend you read through the procedure and refer to the parts diagram on the...

Page 9: ...inal box 9 At the opposite end of the emitter the wire will be clearly visible in the emitter wire tube so gently pull the long wire Fig K out of the tube until it is free 10 One at a time pull the sp...

Page 10: ...WALL BRACKET ASSEMBLY REFLECTOR SIDE COSY XL COM PONENT PART DI AGR AM IMPORTANT SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga On...

Reviews: