![Sola ARGO Starting Manual Download Page 62](http://html.mh-extra.com/html/sola/argo/argo_starting-manual_1312875062.webp)
- 62 -
4-
Once the trap has been positioned in the new configuration,
lock it using the screw and the washers, place the plugs in
the 2 holes that have been left open (Fig. 8.6, 8.7 o 8.8)
5-
When finished, the closing rubbers should be placed and
secured by the quick fasteners (Fig. 8.4).
The dispenser should be configured according to the type of
product and quantity being dispensed.Each dispenser has
a roller that can be configured in sections (e.g. roller with 4
sections, Fig. 8.9). You can install between 1 and 7 sections.
Fig. 8.9
Fig. 8.9
THERE ARE SEVERAL TYPES OF SECTIONS FOR:
HIGH, MEDIUM, LOW AND VERY LOW DOSES
(FIG. 8.10).
VERY HIGH DOSE
VERY HIGH DOSE
HIGH DOSE
HIGH DOSE
LOW DOSE
LOW DOSE
VERY LOW DOSE
VERY LOW DOSE
Fig. 8.10
Fig. 8.10
MEDIUM DOSE
MEDIUM DOSE
16 mm
8 mm
8.1.1 ADJUSTING THE DISPENSER
Follow these steps to set the number of sections to configure
the dispenser for the desired dose:
1-
Remove the R-clip (Fig. 8.11).
2-
Remove the two knobs (Fig. 8.12).
3-
Remove the side support (Fig. 8.13) and remove the roller
(Fig. 8.14).
Fig. 8.11
Fig. 8.11
Fig. 8.12
Fig. 8.12
Fig. 8.13
Fig. 8.13