![Sola ARGO Starting Manual Download Page 17](http://html.mh-extra.com/html/sola/argo/argo_starting-manual_1312875017.webp)
- 17 -
5.2 ELECTRICAL CONNECTIONS
The machine has electrical connections for:
• INDICATOR LIGHTS.
• ISOBUS CONNECTION.
• HYDRAULIC CONTROL AND WORK LIGHTS.
IMPORTANT:
CONNECT ALL OF THE CABLES;
OTHERWISE THE MACHINE WILL NOT WORK.
5.2.1 INDICATOR LIGHTS
All models have a 7-pin connector for indicator lights.
7-pin connector diagram and table (according to ISO 1724):
1
5
4
7
6
3
2
Pin
no.
Stan-
dard
FUNCTION
1
L
Left indicator light
2
54G
Fog light
3
31
Earth
4
R
Right indicator light
5
58R
Right position lamp
6
54
Brake
7
58L
Left position lamp
5.2.2 ISOBUS
The machine must have the 9-pin
connector (according to ISO 11783)
to allow the machine to connect to the
tractor's ISOBUS system.
3
8
7
1
2
6
4
5
9
WHEN TRANSPORTING THE MACHINE ON PUBLIC
ROADS, MAKE SURE THAT THE WORK LIGHTS
ARE SWITCHED OFF.
5.2.3 HYDRAULIC CONTROL AND WORK
LIGHTS
+
-
The machine is powered via the 3-pin
connector (in accordance with standard
DIN 9680).
IMPORTANT:
IF THIS CABLE IS NOT
CONNECTED, IT WILL NOT BE POSSIBLE TO
COMPLETE ANY MOVEMENT WITH THE CHASSIS
OR MARKERS.
To turn the work or hopper lights on or off, follow these steps:
Fig. 5.5
Fig. 5.5
Fig. 5.6
Fig. 5.6