![Snell MV-32 User Manual Download Page 65](http://html1.mh-extra.com/html/snell/mv-32/mv-32_user-manual_1309038065.webp)
MV-32/64 Multiviewer
www.snellgroup.com
Operation
Issue 1 Rev 11
Page 65
© 2014 Snell Limited
The following example settings are entered on the Audio tab (see Fig 50.).
General Settings
:
Display meter 1 tick box: Tick
Display meter 2 tick box: Tick
Audio Meter 1
tab settings for meters on the left of the video tile (Meter W & X)
Use 2 rows of bars tick box: Tick.
Set Scale type, Scale label position, Bar colors, Bar labels, etc. as required.
Audio Meter W
(first row, channels 1 to 2, top left of tile):
Pair 1, Audio Source: Embedded 1 + 2, Audio format: Dolby 5.1 and 2nd row tick box:
Unticked
Audio Meter X
(2nd row, channels 3 to 8, bottom left of tile):
Pair 2, Audio Source: Embedded 3 + 4, Audio format: Auto and 2nd row tick box: Ticked
Pair 3, Audio Source: Embedded 5 + 6, Audio format: PCM and 2nd row tick box: Ticked
Pair 4, Audio Source: Embedded 7 + 8, Audio format: Auto and 2nd row tick box: Ticked
Audio Meter W and X Position and Size Configuration
:
Position (vertical slider, C1): 50 and Position (horizontal slider, D1): 5
Size (vertical slider, A1): 90 and Size (horizontal slider, B1): 10
Audio Meter 2
tab settings for meters on the left of the video tile (Meter Y & Z)
Use 2 rows of bars tick box: Tick.
Set Scale label position, Bar colors, Bar labels, etc. as required.
Audio Meter Y
(1st row, channels 9 to 12, top right of tile):
Pair 5, Audio Source: Embedded 9 + 10, Audio format: PCM and 2nd row tick box:
Unticked
Pair 6, Audio Source: Embedded 11 + 12, Audio format: Auto and 2nd row tick box:
Unticked
Audio Meter Z
(2nd row, channels 13 to 16, bottom right of tile):
Pair 7, Audio Source: Embedded 13 + 14, Audio format: Auto and 2nd row tick box: Ticked
Pair 8, Audio Source: Embedded 15 + 16, Audio format: Dolby 5.1 and 2nd row tick box:
Ticked
Audio Meter Y and Z Position and Size Configuration
:
Position (vertical slider, C2): 50 and Position (horizontal slider, D2): 95
Size (vertical slider, A2): 70 and Size (horizontal slider, B2): 8
Note:
The meter Scale Type selected for meter 1 is also used for meter 2 when both meters are